- 17 -
GB
1.1
TABLE 1: MINIMA SERIES GAS HOBS CAT. II (NATURAL GAS AND L.P.G)
1.2
TECHNICAL CHARACTERISTICS
STRUCTURE
Frame made of AISI 304 stainless steel, panels and base of stainless steel, mounted on height-adjustable feet.
1.3
HOB
TOP
made of AISI 304 stainless steel, watertight.
GRILLS
in vitreous enamelled cast iron for high temperatures (RAL).
BURNERS
in aluminium, burner lid in steel with stabilized flame, direct ignition with safety thermocouple, fixed nozzles for
the various kinds of gas.
GAS COCKS
in die formed brass, provided with relief valve with thermocouple to cut off the gas automatically if the pilot
flame is accidentally extinguished. Adjustment between minimum and maximum flow rate.
CONTROL KNOBS
made of heatproof material.
MODEL
G4SF6
A
602
600
850
960
G1/2”
2
2
2 kW
13,7
1080
1064
1,450
220/240 V
1,8 kW
15W
A
1000
600
850
960
G1/2”
3
3
3,3kW
20,85
1645
1620
2,206
220/240V
1,8 kW
2 x 15/25 W
G6SFA6
A
1000
600
850
960
G1/2”
3
3
2 kW
19,55
1542
1520
2,063
220/240 V
1,8 kW
2 x 15 W
G6SF6
Tipo
m m
m m
m m
m m
“A”
2,7kW
3,15kW
kW
g/h
g/h
m
3
/h
kW
kg
* (1)
Including the thermal capacity of the pilot approx. 200 W
(2)
Voltage: 1 N AC 220 ...240 V 50 Hz
Outside dimensions
Width
Depth
Height
Maximum height
Gas connection
No. Burners and Thermal Capacity
Fast (1)
Triple crown
Oven burner
Total nominal thermal capacity Nominal
Gas consumption (15°C)
L.P.G. G30
L.P.G. G31
Natural gas H-G20
Input *
Voltage
Grill power (2)
Oven lamp
Net weight
Installation and transformation for using other types of gas, if required, must be performed by qualified persons in
accordance with current regulations.
See technical data tables: 1.1 and 2.5
WARNINGS:
If the unit is installed against a wall, the wall needs to withstand temperatures of 80°C and must be fireproof.
1.
TECHNICAL DATA
2.
INSTALLATION INSTRUCTIONS