HEATER ASSEMBLY

NOTE:

   Recommended clearances 

must

 be maintained.

* Remove transit protection material.

TOOLS REQUIRED:

  Drill 

 

10mm masonry drill bit

 

Adjustable spanner

 

Phillips head screwdriver

STEP 1.

Firmly attach the mounting bracket using expanding 
fasteners to a solid wall. 

STEP 2.

Connect an AGA certified stainless steel braided    

 

 hose to the head. Where a hose assembly is to be used 
to connect an appliance it must comply with AS5601 Gas 
Installations pipe sizing tables and shall not exceed 3 
metres in length.  The internal diameter of the hose must 
not be less than 15mm.

STEP 3.

Attach the natural gas regulator between the manual shut 
off valve of the supply line and the heater gas hose or pipe 
and set the outlet pressure at 1kPa.

GAS PIPING

1.   Where it is not practical to install solid tube an AGA 

certified stainless steel braided hose can be installed.  
This hose assembly must comply with AS5601-2004 
Gas Installations, pipe sizing tables and shall not exceed 
3 metres in length.  The internal diameter of the hose 
must not be less than 15mm.

2.  Check with local and state plumbing and heating codes    
 

regarding sizing of the gas lines.

3.  All gas pipe connections to the heater(s) must be sealed  
 

with a gas pipe compound resistant to Natural Gas. 

4.  Installation of a drip leg if required in the gas supply line  
 

going to each heater must conform to AS 5601.

5.  When checking for gas leaks, do no use an open flame.   
 

Use a soap and water solution and check for bubbles  

 

 

indicating gas leakage.

6.  Installation of 1/8” NPT plugged tapping, accessible for    
 

test gauge connections, is required upstream of the gas   

 

supply connection to the heater.

Installation, Operation and Maintenance Instructions

ESSENTIAL INFORMATION

SGA will void any warranty applicable to the product if any 
component of the patio heater is tampered with, or altered.  

To have these units altered or serviced by an unauthorised 
person may render the product inefficient, and at worst 
dangerous.

SERVICING INSTRUCTIONS

Appliances should be serviced at least annually and 
servicing must only be carried out by a Licensed Plumber or 
Authorised Person.  

1.   Remove Guard from Burner Housing. 

2.   Clean the Burner Ports and top with a Soft Brush.  

Inspect and clean all combustion air inlets.

3.   Clean thermocouple tip and spark igniter using a soft 

wire brush.

4.   Check operation of the igniter and the thermocouple.  

Should new parts be required contact the Supplier or 
Sitro Group Australia.

INSTALLATION

Natural Gas Heaters must be installed by an Authorised 
Person.    

Brackets for suspended installation must be permanently 
fixed to a solid structure.   

Positioning of both floor mounted and suspended heaters 
must maintain required clearances.  

i.e. 500mm above, 500mm on all sides and 500mm below 
the heater emitter mesh.   

It is a Standards Australia requirement that an approved 
metal tube such as copper or galvanized steel or an AGA 
certified stainless steel braided hose assembly be utilised to 
convey gas to the burner head, and must be installed by an 
authorised person, i.e. licensed plumber.   

A Natural Gas Patio Heater is not designed for relocation 
to varying locations, so the most preferable permanent 
location should be selected prior to installation.

CARE

We strongly recommend the use of a cover to protect your 
heater when not in use.  

All heaters must have the burner head covered when not in 
use.  This will prevent blockages occurring, which may lead 
to the heater not igniting when required for use on the next 
occasion, or causing the burner not to function efficiently.  

Such blockages can be caused by the accumulation of dust 
on various components in the burner head and by spider 
webs.  Covering the burner head will also assist in reducing 
the weathering effects of the outdoors, as well as corrosion 
from airborne chemicals and sea spray.

Summary of Contents for RH1039 Series

Page 1: ...ns for future use 02314 01 08 FOR OUTDOOR UNDERCOVER USE ONLY PROPANE GAS NATURAL GAS THIS APPLIANCE MUST NOT BE INSTALLED OR USED INDOORS NATURAL GAS APPLIANCE TO BE INSTALLED ONLY BY AN AUTHORISED PERSON THE AUTHORISED PERSON WILL PROVIDE A CERTIFICATE OF COMPLIANCE NOTE TO INSTALLER TEST OPERATION OF APPLIANCE BEFORE LEAVING RH1039 SERIES 3 TILE HEATER Operates for approximately 15hrs on a prop...

Page 2: ...lising an AGA approved regulator a The appliance area must be kept clear and free of combustible materials gasoline and other flammable vapours and liquids b Gas orifices and burner must be kept clear of dirt and cobwebs Flow of combustion and ventilation air to the heater must not be obstructed Cleaning with a soft brush before use and at least every six months is recommended c All gas connection...

Page 3: ...indoors the propane cylinder and the heater must be disconnected and the cylinder stored in accordance with the Standard for Storage and Handling of Liquefied Gases Any modification to the heater not described in the installation instructions may compromise the safety of this appliance Special concern is as follows 1 DO NOT bypass thermocouple safety burner 2 DO NOT operate heater without the guar...

Page 4: ...ter is tampered with or altered To have these units altered or serviced by an unauthorised person may render the product inefficient and at worst dangerous SERVICING INSTRUCTIONS Appliances should be serviced at least annually and servicing must only be carried out by a Licensed Plumber or Authorised Person 1 Remove Guard from Burner Housing 2 Clean the Burner Ports and top with a Soft Brush Inspe...

Page 5: ...aces Combustible materials are considered to be wood compressed paper plant fibres plastic or other materials that are capable of being ignited and burned TOP CLEARANCE 500mm CLEARANCE 2500mm OFF CORD IGNITION CORD GAS CONNECTION POINT 2450mm 400mm 3 Tile 510mm 5 Tile 710mm 230m m ...

Page 6: ...tenance can cause injury or property damage Any modifications or adjustments made to product without prior authority from the manufacturer will void any warranty claims Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment LIGHTING INSTRUCTIONS Warning White smoke may appear around the radiant head during the first minutes of the init...

Page 7: ... see Example 1 Within a partial enclosure that includes an overhead cover and no more than two walls see Example 2 3 Within a partial enclosure that includes an overhead cover and more than two walls the following will apply at least 25 of the total wall area is completely open and at least 30 of the remaining wall area is open and unrestricted see Example 4 5 In the case of balconies at least 20 ...

Page 8: ...Gasmate is a registered trademark of Sitro Group Australia Pty Ltd www sitro com au AberGas Ltd Hamilton N Z www abergas co nz ...

Reviews: