7. The hose must be protected from contact with hot or
sharp surfaces both during use and while in storage.
The hose assembly should be visually inspected prior
to each use of the heater. If excessive abrasion or
wear is evident, or the hose is cut, it must be replaced
prior to operating the heater. The replacement hose
assembly may be obtained from the manufacturer.
8.
DO NOT
use any pressure regulator or hose
assembly other than those supplied with the appliance.
Replacement pressure regulator and hose assembly
must be those specified. Replacement parts may
be obtained from the manufacturer or your local sales
representative.
9. Installation and use of this heater must conform with
local codes or, in the absence of local codes, with the
Standards of Storage and Handling of Liquefied
Petroleum Gases.
10. This heater is designed to operate with a standard 9Kg
propane cylinder with Approved Cylinder Connection.
11. The valve outlet must be maintained in good condition.
When the cylinder is not in use, be sure to cover it with
a dust cap. A leak test should be performed with soapy
water whenever connecting a new cylinder.
NEVER
use
a match to test for leaks.
12. The propane cylinder must be turned off whenever the
heater is not in use. When the heater is to be stored
indoors, the propane cylinder and the heater must be
disconnected and the cylinder stored in accordance
with the Standard for Storage and Handling of Liquefied
Gases.
Any modification to the heater not described in the
installation instructions may compromise the safety of this
appliance. Special concern is as follows:
(1)
DO NOT
bypass thermocouple safety burner;
(2)
DO NOT
operate heater without the guard;
Clothing or other flammable materials should not be hung
from the heater, or placed on or near the heater. The area
above the burner may be extremely hot. Direct contact with
these metal surfaces should be avoided in order to prevent
burns or clothing ignition.
DO NOT locate either the gas or any electrical supply lines
directly over the top of the heater, as overheating may
occur.
The Heater must be installed in a location such that it is
readily accessible for servicing and have no restriction of air
flow to the air inlet of the heater’s casing.
Screw the coupling nut of regulator into the cylinder valve outlet.
(Cylinder not included)
POL CYLINDER CONNECTION DEVICE
3 TILE RADIANT HEATER
Type of Gas
Propane
Natural Gas
Consumption
20 MJ/h
20 MJ/h
Operating Pressure
2.75 kPa
1 kPa
Injector Size
0.7 mm
1.18 mm
Heater specifications can be found on the data label.
5 TILE RADIANT HEATER
Type of Gas
Propane
Natural Gas
Consumption
33 MJ/h
33 MJ/h
Operating Pressure
2.75 kPa
1 kPa
Injector Size
0.7 mm
1.18 mm
Installation, Operation and Maintenance Instructions