(844) 538-7890
www.gaslandchef.com
8350 Patriot Blvd STE B, N. Charleston, SC 29418
12
www.gaslandchef.com
Table 2: How To Convert Gas Source
Adjustment of the reduced valve flow
Valve adjustment
Valve adjustment should be done with the control knob set at burner ON saving
flame position.
Remove the knob and shell, and adjust the flame with a tiny screwdriver(see fig.7
below).
To check the adjusted flame: heat the burner at full open position for 10 minutes.
Then turn the knob into the saving setting. The flame should not extinguish nor
move to the nozzle. If it extinguish or moves to the nozzle, readjust the valves.
Flame selection
As the burners are adjusted correctly, the flame should be light blue, and the
inner flame should be clear. The size of flame depends on the position of the
related control knob.
Fig. 7
Saving flame
Full flame
Flame
Burners
Converting from LPG
to NG
Converting from NG
to LPG
Replace the burner
nozzle according to
the guidelines in table 1
Loosen the adjustment
spindle(see fig.7 below)
and adjust the flame
Replace the burner
nozzle according to
the guidelines in table 1
Loosen the adjustment
spindle(see fig.7 below)
and adjust the flame
Regular