(844) 538-7890
www.gaslandchef.com
8350 Patriot Blvd STE B, N. Charleston, SC 29418
11
www.gaslandchef.com
Table 1: Burners And Nozzle Specifications
Adapting the gas cooktop for different types of gas
Auxiliary
Semi rapid
Rapid
Triple Ring
Supply pressures
NG
LPG
Normal Burner
Capacities(Btu/kWh)
2800/0.82
5000/1.46
6500/1.90
9500/2.78
Normal Burner
Capacities(Btu/kWh)
2800/0.82
5000/1.46
6500/1.90
9500/2.78
Nozzle 1/100
(in/mm)
Nozzle 1/100
(in/mm)
2.9 in/75 mm
3.9 in/100 mm
4.5 in/115 mm
5.1 in/130 mm
2 in/53 mm
2.6 in/68 mm
3.1 in/79 mm
3.6 in/93 mm
12.5mbar
25mbar
Burner
Replacement of burner nozzle: loosen the nozzle with a
dedicated wrench(Fig. 7). Fit the new nozzle according
to the required gas type(see table 1 for reference).
After you have converted the gas cooktop to another gas type, make sure you
have placed a label containing that information on the appliance.
At 15°C and 1013 mbar - dry gas
P.C.I NG 40.1MJ/m³
P.C.I LPG 93.1MJ/m³