Pulse-out I/F Board (M06587A001) Jumper Settings
Jumpers JP4 and JP5
When this board is used in a model 9820 Pump/Dispenser, jumpers JP4 and JP5 are set to the
Q/A position.
illustrates the proper output for using a Pump I/F Board (M06587A001), jumpered to
provide two isolated pulse outputs from a single pulser.
Figure 5: Dual-channel, Single-hose Pulse-out I/F
REMOTE REGISTER
Note
s
: 1) All wiring and conduit runs must conform with all building/fire codes, all Federal,
State, and Local codes, National Electrical Code, (NFPA 70), NFPA 30, and
Automotive and Marine Service Station Code (NFPA 30A) codes and regulations.
Canadian users must also comply with the Canadian Electrical Code.
2) Refer to MDE-4567 9120K & 9820K Series AST Pumps Installation and Operation
Manual or MDE-4652 Atlas 9800 Electronics Field Installation Instructions for
complete installation instructions.