SERVICE WORK ON THE ENGINE 18
115
18.1
Changing the fuel screen
Danger
Fire hazard
Fuel is highly flammable.
The fuel in the fuel tank expands when warm and can escape if overfilled.
–
Do not fuel the vehicle in the vicinity of open flames or lit cigarettes.
–
Switch off the engine for refueling.
–
Make sure that no fuel is spilled; particularly not on hot parts of the vehicle.
–
If any fuel is spilled, wipe it off immediately.
–
Observe the specifications for refueling.
Warning
Danger of poisoning
Fuel is poisonous and a health hazard.
–
Avoid skin, eye and clothing contact with fuel.
–
Immediately consult a doctor if you swallow fuel.
–
Do not inhale fuel vapors.
–
In case of skin contact, rinse the affected area with plenty of water.
–
Rinse the eyes thoroughly with water, and consult a doctor in case of fuel contact with the eyes.
–
Change your clothing in case of fuel spills on them.
Note
Environmental hazard
Improper handling of fuel is a danger to the environment.
–
Do not allow fuel to enter the groundwater, the soil, or the sewage system.
F03259-10
–
Clean quick release coupling
1
thoroughly with compressed air.
Info
Under no circumstances should dirt enter into the fuel line.
Dirt in the fuel line clogs the injection valve!
–
Disconnect the quick release coupling.
Info
Remaining fuel may flow out of the fuel hose.
–
Pull fuel screen
2
out of the connecting piece.
–
Insert the new fuel screen all the way into the connecting piece.
–
Spray silicone spray onto a lint-free cleaning cloth and lightly lubri-
cate the O-ring of the quick-release coupling.
Silicone spray (
–
Join the quick release coupling.
Danger
Danger of poisoning
Exhaust gases are toxic and inhaling
them may result in unconsciousness and death.
–
Always make sure there is sufficient ventilation when
running the engine.
–
Use effective exhaust extraction when starting or run-
ning the engine in an enclosed space.
–
Start the engine and check the response.
Summary of Contents for EC 350F
Page 1: ...OWNER S MANUAL 2021 EC 350F Art no 3215013en ...
Page 2: ......
Page 40: ...10 SERVICE SCHEDULE 38 One time interval Periodic interval ...
Page 138: ...23 TECHNICAL DATA 136 Screw in fitting cooling system M24x1 5 18 Nm 13 3 lbf ft Loctite 243 ...
Page 150: ... 3215013en 3215013en 10 2020 Stallhofnerstraße 3 5230 Mattighofen Austria http www gasgas com ...