background image

MGC Pump User’s Manual

UM-MGC-P v1.06 

19 of 19

Note: 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of 

the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference when the equipment 

is operated in a commercial environment.  This equipment generates, uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.

 

   

 

              

LIMITED WARRANTY

Gas Clip Technologies (“GCT”) warrants this product to be free from defects in material and workmanship under normal use 

and service for a period of two years beginning upon the date of activation for all Multi Gas Clip products. Date of activation 

allowance is limited to the “Activate before…” date provided on the shipment box label. This warranty extends only to the 

sale of new and unused products to the original buyer. GCT’s warranty obligation is limited, at GCT’s option, to refund of 

the purchase price, repair, or replacement of a defective product that is returned to a GCT authorized service center within 

the warranty period. In no event shall GCT’s liability hereunder exceed the purchase price actually paid by the buyer for the 

product. This warranty does not include: (1) Fuses, disposable batteries, or routine replacement of parts due to the normal 

wear and tear of the product arising from use. (2) Any product which in GCT’s opinion, has been misused, altered, neglected 

or damaged by accident or abnormal conditions of operation, handling, or use. (3) Any damage or defects attributable to 

repair of the product by any person other than the authorized dealer, or installation of unapproved parts on the product. 

The obligations set forth in this warranty are conditional on: (1) Proper storage, installation, calibration, use, maintenance, 

and compliance with the user’s manual instructions and any other applicable recommendations of GCT. (2) The buyer 

promptly notifying GCT of any defect and, if required, promptly making the product available for correction. No goods shall 

be returned to GCT until receipt by the buyer of instructions from GCT. (3) The right of GCT to require that the buyer provide 

proof of sale or packing slip to establish that the product is within the warranty period. The buyer agrees that this warranty 

is the buyer’s sole and exclusive remedy and is in lieu of all other warranties, expressed or implied, including, but not 

limited to, any implied warranty or merchantability or fitness for a particular purpose. GCT shall not be liable for any special, 

indirect, incidental, or consequential damages or losses, including loss of data, whether arising from breach of warranty 

or based on contract, tort, or reliance on any other theory. Some countries or states do not allow limitation of the term of 

an applied warranty, or exclusion or limitation of incidental or consequential damages. The limitations and exclusions of 

this warranty may not apply to every buyer. If any provision of this warranty is held invalid or unenforceable by a court of 

competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. 

Gas Clip Technologies, Inc.

305 W. FM 1382, Ste. 540, Cedar Hill, TX 75104

Phone:  +1 (972) 775-7577   •   Toll Free:  1 (877) 525-0808  •   Fax:  +1 (972) 775-2483

[email protected]   •  www.gascliptech.com

Summary of Contents for Infrared

Page 1: ...User s Manual G A S C L I P T E C H C O M Multi Gas Clip Pump Infrared Multi Gas Clip Pump Pellistor...

Page 2: ...Detector Records Logs 7 Event Log 7 Bump Log 7 Calibration Log 7 Data Logs 7 How to Retrieve Logs Using the GCT IR Link 8 Detector Options Menus 9 Adjustible Options 9 Main Menu 11 Status Menu 11 Opt...

Page 3: ...nes lead compounds e g tetraethyl lead sulfur compounds phosphorus halogenated hydrocarbons and aerosols Exposure to poisons may impair the accuracy and or response time of the detector This applies t...

Page 4: ...imiter des nettoyants base d alcool et d agrumes des silicones des compos s de plomb par exemple plomb t tra thyle compos s soufr s phosphore hydrocarbures halog n s et a rosols L exposition des poiso...

Page 5: ...ion 1 Power Button 2 Audible Port 3 Display 4 Alarm Bar LEDs 5 Maintenance LEDs 6 IR Communication Window 7 Gas Inlet 8 Filter Window 9 Certification Label 10 Model and Serial Number 11 Gas Exhaust 12...

Page 6: ...bump test the calibration bottle will be displayed when it is time to apply gas The battery is displayed in 3 bars as well as a percentage The percentage calculation is approximate and can be used to...

Page 7: ...st LED flash Pump Blocked Fast beep Fast vibration Fast LED flash Sensor Error Fast beep Fast vibration Fast LED flash Low Battery 20 minutes remaining single beep flash and battery icon on 10 minutes...

Page 8: ...w for activation the detector will display LOW BAT and then turn off again Once activated the detector will begin to display gas readings immediately Each sensor will show a chasing O for the sensor r...

Page 9: ...the alarm condition occurs inside of the MGC Pump Dock or when the detector is manually bump tested according to the Manual Bump Test Instructions The detector records the bump status for each test Da...

Page 10: ...r 4 Select what kind of logs you want to download a Event Logs Only b Events Partial Data Log last week of data c Events New Data Logs Only All data logs from last time you pulled the logs to current...

Page 11: ...The detector s firmware version The TWA alarm limits The STEL alarm limits The LOW alarm limits The HIGH alarm limits Adjustable Options The detector s options are configured using the IR Link and th...

Page 12: ...ble Individual sensors can be disabled A disabled sensor is completely removed from the detector s display for sensor readings alarm limits and calibrations Caution A disabled sensor will not measure...

Page 13: ...empty the detector will skip ahead If the startup message does not fit on one screen it will scroll right to left twice Sub Menu Prompts Pressing the button during a sub menu prompt will cause the de...

Page 14: ...10 minutes remaining and then continuously for the last 5 minutes of run time When the battery has expired the detector will give 5 long beeps and flashes display OFF and then shut down To charge the...

Page 15: ...e detector will return to normal operation in alarm and the bump due date will be reset If a bump test interval has not been programmed into the detector users may simply apply gas to the detector dur...

Page 16: ...ternal pump and sensor areas free of water and debris If these filters become blocked then the detector will be unable to continue sampling and the pump will enter into a pump blocked alarm Looking at...

Page 17: ...e back of the detectors that can clip on to clothing or belts 6 Telescoping Probe P N MGC TSPROBE Metal probe that extends to 6 foot MGC Pump Probe Case P N MGC PUMP TSCASE Holster for MGC Pump with s...

Page 18: ...nal pump motor Replacement Particulate Filters P N MGC PFILTER 10 and MGC PFILTER 50 replacement particulate hard plastic filters in either a 10 pack or a 50 pack Replacement Hydrophobic Filters P N M...

Page 19: ...inuous 1 second data logging 2 months typical capacity Tests Full function self test upon activation Sensors battery and circuitry tests run continuously Ingress Protection IP 67 Warranty Full 2 years...

Page 20: ...ntrins que Class I Division 1 Groups A B C and D T4 Class I Zone 1 AEx d ia IIC T4 Gb 20 Ta 50 C 3 8Vdc nominal ANSI ISA 12 13 01 2000 C22 2 No 152 M1984 UL 916 4th Edition UL 913 8th Edition UL 60079...

Page 21: ...or use 3 Any damage or defects attributable to repair of the product by any person other than the authorized dealer or installation of unapproved parts on the product The obligations set forth in this...

Reviews: