MGC Pump User’s Manual

UM-MGC-P v1.06 

10 of 19

Maintenance Notification-

 If maintenance notification is enabled, the detector will periodically flash the 

maintenance LED. Otherwise, if the option is disabled, the detector will only show the maintenance text on the 

display.

Pump Test-

 Will require the pump to be tested (block and unblock) on startup.

Dock Lock-

 Dock Lock prevents calibrations and bump tests without the use of the IR Link or the MGC Pump 

Dock.

Latching Alarms-

 Latched alarms will hold the detector and its display in its peak alarm condition until the button 

is pressed.

Auto-Zero-

 The detector can optionally zero the sensors with every power-up.

TWA Method-

 The algorithm used to calculate the TWA can be set to either an average over a moving window 

(OSHA) or as a cumulative average (ACGIH).

TWA Interval-

 The TWA interval defines the time frame over which the long-term average is calculated. Default is 

8 hours.

STEL Interval- 

The STEL interval defines the time frame over which the short-term average is calculated. Default is 

15 minutes.

Sensor Enable/Disable-

 Individual sensors can be disabled. A disabled sensor is completely removed from the 

detector’s display for sensor readings, alarm limits and calibrations.

                            

 Caution: A disabled sensor will not measure gas or detect alarm conditions .

Bump Interval-

 The bump interval controls how often the detector notifies the user to bump test the sensors. The 

interval can be individually adjusted for each sensor from 1 to 365 days. Default is N/A (disabled).

Calibration Interval-

 The calibration interval controls how often the detector notifies the user to calibrate the 

sensors. The interval can be individually adjusted for each sensor from 1 to 365 days (default is 365 days) except 
for the pellistor sensor which can be adjusted from 1-180 days (default is 180 days).

Calibration Gas-

 When the detector is calibrated, it scales the sensor readings to match the concentrations of the 

applied gases. The calibration gas concentrations can be adjusted to match the respective levels contained within 
the gas bottle. Default is: 25ppm H

2

S, 100ppm CO, 18% O

2

 and 50%LEL (2.5%vol CH

4

).

Language:

 The detector will display all of its text prompts in any of the following languages: English, German, 

French, Spanish, Italian or Portuguese.

•  Note: OL, Err and sensor icons remain the same for all languages.

Summary of Contents for Infrared

Page 1: ...User s Manual G A S C L I P T E C H C O M Multi Gas Clip Pump Infrared Multi Gas Clip Pump Pellistor...

Page 2: ...Detector Records Logs 7 Event Log 7 Bump Log 7 Calibration Log 7 Data Logs 7 How to Retrieve Logs Using the GCT IR Link 8 Detector Options Menus 9 Adjustible Options 9 Main Menu 11 Status Menu 11 Opt...

Page 3: ...nes lead compounds e g tetraethyl lead sulfur compounds phosphorus halogenated hydrocarbons and aerosols Exposure to poisons may impair the accuracy and or response time of the detector This applies t...

Page 4: ...imiter des nettoyants base d alcool et d agrumes des silicones des compos s de plomb par exemple plomb t tra thyle compos s soufr s phosphore hydrocarbures halog n s et a rosols L exposition des poiso...

Page 5: ...ion 1 Power Button 2 Audible Port 3 Display 4 Alarm Bar LEDs 5 Maintenance LEDs 6 IR Communication Window 7 Gas Inlet 8 Filter Window 9 Certification Label 10 Model and Serial Number 11 Gas Exhaust 12...

Page 6: ...bump test the calibration bottle will be displayed when it is time to apply gas The battery is displayed in 3 bars as well as a percentage The percentage calculation is approximate and can be used to...

Page 7: ...st LED flash Pump Blocked Fast beep Fast vibration Fast LED flash Sensor Error Fast beep Fast vibration Fast LED flash Low Battery 20 minutes remaining single beep flash and battery icon on 10 minutes...

Page 8: ...w for activation the detector will display LOW BAT and then turn off again Once activated the detector will begin to display gas readings immediately Each sensor will show a chasing O for the sensor r...

Page 9: ...the alarm condition occurs inside of the MGC Pump Dock or when the detector is manually bump tested according to the Manual Bump Test Instructions The detector records the bump status for each test Da...

Page 10: ...r 4 Select what kind of logs you want to download a Event Logs Only b Events Partial Data Log last week of data c Events New Data Logs Only All data logs from last time you pulled the logs to current...

Page 11: ...The detector s firmware version The TWA alarm limits The STEL alarm limits The LOW alarm limits The HIGH alarm limits Adjustable Options The detector s options are configured using the IR Link and th...

Page 12: ...ble Individual sensors can be disabled A disabled sensor is completely removed from the detector s display for sensor readings alarm limits and calibrations Caution A disabled sensor will not measure...

Page 13: ...empty the detector will skip ahead If the startup message does not fit on one screen it will scroll right to left twice Sub Menu Prompts Pressing the button during a sub menu prompt will cause the de...

Page 14: ...10 minutes remaining and then continuously for the last 5 minutes of run time When the battery has expired the detector will give 5 long beeps and flashes display OFF and then shut down To charge the...

Page 15: ...e detector will return to normal operation in alarm and the bump due date will be reset If a bump test interval has not been programmed into the detector users may simply apply gas to the detector dur...

Page 16: ...ternal pump and sensor areas free of water and debris If these filters become blocked then the detector will be unable to continue sampling and the pump will enter into a pump blocked alarm Looking at...

Page 17: ...e back of the detectors that can clip on to clothing or belts 6 Telescoping Probe P N MGC TSPROBE Metal probe that extends to 6 foot MGC Pump Probe Case P N MGC PUMP TSCASE Holster for MGC Pump with s...

Page 18: ...nal pump motor Replacement Particulate Filters P N MGC PFILTER 10 and MGC PFILTER 50 replacement particulate hard plastic filters in either a 10 pack or a 50 pack Replacement Hydrophobic Filters P N M...

Page 19: ...inuous 1 second data logging 2 months typical capacity Tests Full function self test upon activation Sensors battery and circuitry tests run continuously Ingress Protection IP 67 Warranty Full 2 years...

Page 20: ...ntrins que Class I Division 1 Groups A B C and D T4 Class I Zone 1 AEx d ia IIC T4 Gb 20 Ta 50 C 3 8Vdc nominal ANSI ISA 12 13 01 2000 C22 2 No 152 M1984 UL 916 4th Edition UL 913 8th Edition UL 60079...

Page 21: ...or use 3 Any damage or defects attributable to repair of the product by any person other than the authorized dealer or installation of unapproved parts on the product The obligations set forth in this...

Reviews: