48
49
EN
EN
Technical data
Specification
Standards/directives:
IEC 61851-1 and IEC TS 61439-7
Installation:
on wall or Garo Wallbox stand
Voltage rating:
230V/400 50Hz
Installation systems:
TT, TN and IT systems
Charging type:
Mode 3
IP classification:
IP44
Mechanical impact
resistance:
IK08
Application temperature:
-25
0
C–+40
0
C
Storage temperature:
-35
0
C–+55
0
C
Installation height:
0.5–1.5 metres above ground/land to lower edge of
charger.
Weight:
around 3 kg including socket
3.8–4.1 kg including cable and connector, single-phase
5,4 kg including cable and connector, three-phase
Technical data
Troubleshooting
Instructions /
Troubleshooting
Indication
Type of fault
Measure
Constant red light
The residual-current or
personal protective current
breaker
has been tripped.
Reset. Refer to section on
Resetting the residual-current
or personal protective current
breaker.
Constant yellow light
Broken cable
Check cable
Flashing yellow light
Motor lock socket not in
latched position.
Contact a qualified
electrician
No indication
Check supply fuse
If the measure advised does not help, contact a qualified fitter.