190-02246-11
GI 275 Part 23 AML STC Maintenance Manual
Rev. 1
Page 5-35
10. Touch the
Test Results
button and then
Rundown Test Results
button.
a. The results are displayed the date the test was performed and how many minutes until the
battery ran down.
11. For aircraft that are approved for flight over 25,000 feet, a rundown time of at least 60 minutes is
required to be considered a PASS.
For aircraft that are only approved for flight at 25,000 feet or less, a rundown time of at least
30 minutes is required to be considered a PASS.
12. If the test results were not a PASS as described in the previous step, the battery must be replaced
using the procedure in Section 5.5.