______________________________________________________________________________
____________________________________________________________________________
LMM for the Kodiak 100
Page 5-17
190-02102-00 Rev.4
2. To Reinstall:
a) Inspect the connector for damaged pins (3).
b) Place the configuration module (1) in position and insert the connector.
c) Insert the connector into the configuration module (1).
d) Assembly of the connector is the reverse of disassembly.
3. Post-Installation Instructions:
a) If the GRS 79 AHRS Configuration Module is replaced, all three GRS.GMU
calibration procedures must be performed. Refer to
.
b) If the GDC 72 Configuration Module is replaced, configuration settings must
be reloaded to the GDC 72. Refer to
.
c) If the Master Configuration Module is replaced:
i)
Start the G1000 NXi system in configuration mode.
ii) Go to the Configuration Upload Page on the PFD.
iii) Press the UPDT CFG softkey.
4. If both the PFD and the Master Configuration Module are replaced, configuration
must be reloaded to all LRUs in the G1000 NXi system except the GRS 79, GMU
44B, and GDC 72. Refer to
.
Uncontrolled if Printed