Page 4-42
LMM for the Kodiak 100
190-02102-00 Rev.4
COM2 MANIFEST
COM2 has incorrect
software installed and
communication has
halted.
• Load the correct software.
COM2 PTT
The COM2 push-to-talk
(PTT) key line is stuck in
the enabled state.
• Press the PTT switch to
cycle its operation.
• Check the PTT switch and
wiring.
• Check the GIA to GMA
interconnect.
• If the fault persists, replace
the GIA.
• If the fault persists, replace
the GMA.
COM2 RMT XFR
The COM2 remote
transfer key line is stuck in
the enabled state.
• Press the remote transfer
switch to cycle operation.
• Check the remote transfer
switch and wiring.
• If the fault continues,
replace the GIA.
COM2 SERVICE
A fault has been detected
in the COM subsystem of
GIA2. COM2 may still be
usable.
• Cycle power to the GIA.
• Replace the GIA.
COM2 TEMP
The system has detected
an over temperature
condition in COM2. The
transmitter is operating at
reduced power.
• Check the fan, wiring, and
air tubing for proper
ventilation (if applicable).
• Replace the cooling fan if
not able to find it is
operating properly.
• If the problem persists,
replace the GIA.
FAILED PATH
A data path connected to
a GDU and/or GIA has
failed.
• Determine which data path
has failed and check wiring
continuity for the failed
path.
• If the problem persists,
replace the affected LRU.
Table 4-5. GIA 64W System Messages (Continued)
System Message
Cause
Recommended Actions