INSTALLATION/OPERATION & SERVICE MANUAL - 1&2 PLATEN
GARLAND CLAMSHELL GRILLS WITH PRODUCT RECOGNITION
PART #4527466 (12 Aug 2011)
Page 12
INPUT SPECIFICATIONS
SUPPLY
REQUIRED
TOTAL
KW
LOAD
NOMINAL AMPS PER LINE
208V
240V
L1
L2
L3
L1
L2
L3
INPUT
21.2
59
59
59
51
51
51
Input Specifi cations, ELECTRIC FULL SIZE Grills, MWE2W, Canada:
SUPPLY
REQUIRED
TOTAL
KW
LOAD
NOMINAL AMPS PER LINE
208V
240V
L1
L2
L3
L1
L2
L3
INPUT
16.2
48.4
38.2
48.4
42
33.2
42
Input Specifi cations, ELECTRIC SLIM Grills, MWE2S, Canada:
SUPPLY
REQUIRED
TOTAL
KW
LOAD
NOMINAL AMPS PER LINE
208V
220V
240V
L1
L2
L3
L1
L2
L3
L1
L2
L3
INPUT 1
10.6
29.5
29.5
29.5
27.9
27.9
27.9
25.5
25.5
25.5
INPUT 2
10.6
29.5
29.5
29.5
27.9
27.9
27.9
25.5
25.5
25.5
Input Specifi cations, ELECTRIC FULL SIZE Grills, MWE2W, United States:
SUPPLY
REQUIRED
TOTAL
KW
LOAD
NOMINAL AMPS PER LINE
208V
220V
240V
L1
L2
L3
L1
L2
L3
L1
L2
L3
INPUT 1
8.1
24.2
24.2
24.2
22.9
22.9
22.9
21
21
21
INPUT 2
8.1
24.2
24.2
24.2
22.9
22.9
22.9
21
21
21
Input Specifi cations, ELECTRIC SLIM Grills, MWE2S, United States:
Input Specifi cations, ELECTRIC FULL SIZE Grills, MWE2W, CE Approved & Export:
MWE2S,CE WYE CONFIG
SUPPLY
REQUIRED
TOTAL
KW
LOAD
NOMINAL AMPS PER LINE
MENNEKES
PLUG &
RECEPTACLE
MAY BE
REQUIRED
380V (220V-N)
400V (230V-N)
415V (240V-N)
L1/N
L1
L2
L3
L1/N
L1
L2
L3
L1/N
L1
L2
L3
INPUT
16.5
0.3
33.6
20.8
20.8
0.25
31.9
19.8
19.8
0.24
30.7
19.1
19.1
748
Input Specifi cations, ELECTRIC SLIM Grills, MWE2S, CE Approved & Export:
MWE2W,CE WYE CONFIG
SUPPLY
REQUIRED
TOTAL
KW
LOAD
NOMINAL AMPS PER LINE
MENNEKES
PLUG &
RECEPTACLE
MAY BE
REQUIRED
380V (220V-N)
400V (230V-N)
415V (240V-N)
L1/N
L1
L2
L3
L1/N
L1
L2
L3
L1/N
L1
L2
L3
INPUT
22.0
2.10
33.5
33.4
33.4
2.00
31.9
31.8
31.8
1.98
30.7
30.6
30.6
748
Summary of Contents for MWE2W