TO SET THE REED SWITCHES
In order to ensure that the platen reed switches are in
their proper location, you must ensure that the distance
of the magnet is the correct distance away from the
switch (located inside the upper platen).
Magnet Assy
Magnet Assy
1) Enter the “LEVEL/REED SW” mode:
a) With the controller display ON and either
displaying the current menu item or displaying
“OFF” PRESS and HOLD the
button for 3
seconds. Controller will display previously
selected menu item and its corresponding item
number OR “Standby / Menu Item”.
b) PRESS the
AND
arrow buttons TOGETHER.
“CONFIGURE” will appear in the display.
c) PRESS
the 2X. “CALIBRATION” appears.
d) PRESS the button. “LEVEL/REED SW” appears.
e) PRESS
the button. “NO” will begin to fl ash.
f ) PRESS
the button. “NO” will change to “YES”.
g) PRESS the button. “YES” will stop fl ashing.
h) Press the GREEN button to lower the platen.
2) Remove the reed switch
grease caps.
3) Remove the reed switch
locking caps.
4) Using the Platen
Adjusting Tool, screw
the magnet down
(clockwise) UNTIL the
controller sounds a hi
pitched BEEP.
CAUTION: DO NOT USE A
SCREWDRIVER TO SCREW
THE MAGNET.
5) SLOWLY screw the
magnet UP (counter-
clockwise) UNTIL the
hi-pitched BEEP STOPS.
6) Screw the magnet
counter-clockwise one,
(1), more
full turn (360˚) .
7) Repeat the procedure for the additional reed switches.
8) Screw down reed switch
locking caps.
NOTE: IT IS IMPERATIVE
THAT YOU HOLD THE
MAGNET IN PLACE WHEN
SCREWING DOWN THE
LOCKING CAP.
8) After setting the reed switches as desribed, press
the
GREEN button to perform a Forced Auto
Calibration..
9) Reinstall grease caps.