![Garland moisture+ MPGD10D Service Manual Download Page 54](http://html1.mh-extra.com/html/garland/moisture-mpgd10d/moisture-mpgd10d_service-manual_3752509054.webp)
Part # MPSM07 (03/24/08)
Page 54
TESTING & TROUBLESHOOTING
Direct Spark Ignition Detail
MPO Direct Spark Ignition Specifications and Module Box Connections
Manufacturer
JOHNSON CONTROLS INC .
Vendor Part #
G760BAD-1
Ignition Type
Direct Spark
High Voltage Cable Wire
Stranded
Ignition Source
High Voltage Spark
Maximum Cable Length
48” (1,220mm)
Flame Detection Means
Flame Rectification
Flame Detection Types
Remote Sensing
Minimum Flame Current
0 .3 Microampere
Flame Failure
Response Time
0 .8 Seconds Maximum
Spark Gap
0 .1” (2 .5mm)
Ignition Retrials
3
Safety Times
4 Seconds
Waiting Times
0 Seconds
Interpurge
30 Seconds
Loss Of Flame Signal Retrials
4 (Five Total Ignition Attempts)
Operation Current
24 VAC, 50/60 HZ, Nominal, 0 .2A
N Main Valve
Contact Rating (MV)
2A Continuous, 5A Inrush
Ambient Operating And
Storage Fluttered
-40 to 158 °F (-40 to 70°C)
Humidity
95% RH non-condensing
Wire Connections
Spark Options
RAJAH Connector
GROUND
5
LED
THS 2
M.V. 3
SENSE 4
Summary of Contents for moisture+ MPGD10D
Page 2: ...Part MPSM07 03 24 08 Page...
Page 4: ...Part MPSM07 03 24 08 Page...
Page 5: ...Part MPSM07 03 24 08 Page 5 Section One Operation Installation Manual...
Page 38: ...Part MPSM07 03 24 08 Page 38...
Page 39: ...Part MPSM07 03 24 08 Page 39 Section Two Service...
Page 60: ...Part MPSM07 03 24 08 Page 60...
Page 61: ...Part MPSM07 03 24 08 Page 61 Section Three Parts List...
Page 66: ...Part MPSM07 03 24 08 Page 66 2006 Burners Gas Components BURNERS GAS COMPONENTS...
Page 72: ...Part MPSM07 03 24 08 Page 72 Revised_Plumbing Components Gas DOOR COMPONENTS GAS MOISTURE...
Page 77: ...Part MPSM07 03 24 08 Page 77...
Page 78: ...Part MPSM07 03 24 08 Page 78...
Page 79: ...Part MPSM07 03 24 08 Page 79...
Page 80: ......