![Garland moisture+ MPGD10D Service Manual Download Page 15](http://html1.mh-extra.com/html/garland/moisture-mpgd10d/moisture-mpgd10d_service-manual_3752509015.webp)
Part # MPSM07 (03/24/08)
Page 15
Turn on the main gas valve .
Remove the lower front trim cover . Drop the control panel
and leak test all fittings and connections upstream from the
service valve located on the redundant combination gas
valve . Should any gas leaks be detected turn OFF the main
gas valve, correct the problem and begin the test again .
Remove the blanking plug from the manifold test spigot and
connect a pressure test gauge .
Open the manual gas valve located behind the redundant
combination gas valve .
Activate the control panel and set the oven to the desired
temperature . The burner will now ignite .
During installation there will be air in the gas line . This air will
have to bleed off before ignition can occur . Wait five minutes
after each attempt to bleed the air from the lines .
Turn on all appliances supplied by the same gas line and
verify that the manifold pressure is 4 .5” WC for natural gas or
10” WC for propane gas .
GAS MODEL TESTING & LIGHTING INSTRUCTIONS
After the correct pressure has been verified, turn off the oven
and remove the pressure gauge from the manifold pressure
test spigot . Re-install the blanking plug .
Check all fittings again . Correct any leaks and begin the test
again .
Replace all control panels, service panels and covers before
operation .
All electronic ignition systems are supplied with a redundant
gas valve . Therefore, the oven is not supplied with an external
pressure regulator .
To Conserve Energy:
Do not waste energy by leaving the controls at high
temperature settings during idle periods . Lower settings will
keep the oven warm and ready for the next use period .
Figure 7
.
A
TO ACCESS THE MANUAL SHUTOFF,
REMOVE THE THUMBSCREW FROM
THE CONTROL PANEL, UNPLUG
THE CONTROL FROM THE WIRING HARNESS,
AND REMOVE THE CONTROL PANEL TO
EXPOSE THE MANUAL SHUTOFF VALVE.
*** VIEW SHOWN
WITHOUT THE
BODY SIDE
FOR CLARITY***
3/4” MANUAL
GAS VALVE
A
REMOVE PLUG BUTTON TO
ACCESS PRESSURE ADJUSTMENT
FOR THE MANIFOLD
SAFETY SHUTOFF
SWITCH
FOR GAS VALVE
DETAIL A
Summary of Contents for moisture+ MPGD10D
Page 2: ...Part MPSM07 03 24 08 Page...
Page 4: ...Part MPSM07 03 24 08 Page...
Page 5: ...Part MPSM07 03 24 08 Page 5 Section One Operation Installation Manual...
Page 38: ...Part MPSM07 03 24 08 Page 38...
Page 39: ...Part MPSM07 03 24 08 Page 39 Section Two Service...
Page 60: ...Part MPSM07 03 24 08 Page 60...
Page 61: ...Part MPSM07 03 24 08 Page 61 Section Three Parts List...
Page 66: ...Part MPSM07 03 24 08 Page 66 2006 Burners Gas Components BURNERS GAS COMPONENTS...
Page 72: ...Part MPSM07 03 24 08 Page 72 Revised_Plumbing Components Gas DOOR COMPONENTS GAS MOISTURE...
Page 77: ...Part MPSM07 03 24 08 Page 77...
Page 78: ...Part MPSM07 03 24 08 Page 78...
Page 79: ...Part MPSM07 03 24 08 Page 79...