TESTING & TROUBLESHOOTING
Component Readings
Spritzer
Solenoid
Valve Coil
Resistance
22
Ω
Dual Stage Gas
Valve
Solenoid
Resistance
Pilot Valve = 28 .5
Ω
Main Valve = 28
Ω
Fan Motor And Blower Wheel
The blower wheel and fan motor are considered to be one
complete assembly . Therefore, if the motor is determined to
require replacement, the blower wheel must be replaces as
well .
Garland sets the wheel at the factory with a specifi c gap
setting.
GROUND
5
LED
THS 2
M.V. 3
SENSE 4
Direct Spark
Ignition Module
3 Trials
4 Seconds Per Trial
No Retry
Minimum Acceptable
µa Reading
≥
0 .3
Heat & Control
Board Transformer
Primary = 21 .5
Ω
Secondary = 1 .5
Ω
Summary of Contents for moisture+ MPGD10D
Page 2: ...Part MPSM07 03 24 08 Page...
Page 4: ...Part MPSM07 03 24 08 Page...
Page 5: ...Part MPSM07 03 24 08 Page 5 Section One Operation Installation Manual...
Page 38: ...Part MPSM07 03 24 08 Page 38...
Page 39: ...Part MPSM07 03 24 08 Page 39 Section Two Service...
Page 60: ...Part MPSM07 03 24 08 Page 60...
Page 61: ...Part MPSM07 03 24 08 Page 61 Section Three Parts List...
Page 66: ...Part MPSM07 03 24 08 Page 66 2006 Burners Gas Components BURNERS GAS COMPONENTS...
Page 72: ...Part MPSM07 03 24 08 Page 72 Revised_Plumbing Components Gas DOOR COMPONENTS GAS MOISTURE...
Page 77: ...Part MPSM07 03 24 08 Page 77...
Page 78: ...Part MPSM07 03 24 08 Page 78...
Page 79: ...Part MPSM07 03 24 08 Page 79...
Page 80: ......