COMPONENT IDENTIFICATION
Cavity Temperature Controls
Service Overview
•
Spritzer (Water Inlet) –
Purpose: This temperature switch assures water injection
will not be available below a cavity temperature that
would allow excessive puddle buildup on the cavity floor .
The switch will close at a temperature of 225°F on rise .
This low, but slightly above superheat value of water
temperature will enable a preference of low temperature
cooking .
•
Control Compartment Ambient Temperature –
Purpose: This control will automatically run the cooling fan
in the control compartment if the temperature reaches,
or exceeds 150°F . This function will assure maximum
air extraction of hot ambient control compartment air
during continuous operation, and intake of cooler outside
ambient air .
Spritzer
Temperature
Control
Cooling
Fan
Control
NOTE: Water can only be injected
after the oven has preheated to at
least 225°F (107°C) .
Summary of Contents for moisture+ MPGD10D
Page 2: ...Part MPSM07 03 24 08 Page...
Page 4: ...Part MPSM07 03 24 08 Page...
Page 5: ...Part MPSM07 03 24 08 Page 5 Section One Operation Installation Manual...
Page 38: ...Part MPSM07 03 24 08 Page 38...
Page 39: ...Part MPSM07 03 24 08 Page 39 Section Two Service...
Page 60: ...Part MPSM07 03 24 08 Page 60...
Page 61: ...Part MPSM07 03 24 08 Page 61 Section Three Parts List...
Page 66: ...Part MPSM07 03 24 08 Page 66 2006 Burners Gas Components BURNERS GAS COMPONENTS...
Page 72: ...Part MPSM07 03 24 08 Page 72 Revised_Plumbing Components Gas DOOR COMPONENTS GAS MOISTURE...
Page 77: ...Part MPSM07 03 24 08 Page 77...
Page 78: ...Part MPSM07 03 24 08 Page 78...
Page 79: ...Part MPSM07 03 24 08 Page 79...
Page 80: ......