6 . Cap the extreme right and or left drain tube by installing
the gasket 17 and cover 18 on the end of the drain tube .
Clamp in place as shown in Fig . 3 .
7 . All remaining drain tube joints must be fastened . Place
gasket 17 between joint and fasten with clamps as shown
in Fig . 3 .
8 . Special note concerning the use of item 1 and 8 .
A . The first Fryer to the right of the filter uses item 1
– 12” drain tube and any successive Fryer uses Item 8
– 17” drain tube . Refer to Fig . 1 .
B . If there is only one Fryer to the left of the filter use
item 1 – 12” drain tube . If there is more than one Fryer
to the left use item 8 – 17” drain tube . Use item 8 on
any successive Fryers until you reach the last Fryer on
the left use item
1 – 12” tube .
10-2 WING NUT
BALL VALVE
13
1
17
15
16
17
18
1211
FIGURE 2
10-2 x 5/8 BOLT
10-2 HEX NUT
10
CLAMP DETAIL
FIGURE 3
Wire Interconnection
1 . Two wires #27 and #28 originating at the filter must be
wired to the adjacent Fryer . From that Fryer to successive
Fryers wires #29 and #30 must be connected . Refer to
wiring Diagram to proper connections .
Wiring diagram is attached to inside of door panel .
Electrical Grounding Instructions
Filter Quick, when installed, must be electrically grounded in
accordance with local codes, or in the absence of local codes
with the National electrical code ANSI/NFPA 70-198 .
WARNING: This appliance is equipped with a three-prong
(grounding) plug for your protection against shock hazard
and should be plugged directly into a properly grounded
three-prong receptacle . Do not cut or remove the grounding
prong from this plug .
FRYER FRYER
FRYER
FRYER FRYER FRYER
FRYER
FRYER
FILTER
FILTER
7
7
7
7
7
7
7
7
1
1
1
1
2
2
3
3
3
3
3
3
3
3
5
5
5
5
5
5
5
5
5
5
6
6
6
6
8
8
8
9
9
FIGURE 1
INSTALLATION Continued
Summary of Contents for Master Series
Page 2: ...Part 1382606 Rev 2 12 07 Page...
Page 12: ......