Installation  

 

RTCSmp Built-In Temperature Controlled Hold-Line 

 

 

14 

 

Part # 4532287  Rev 2 (1/20/14) 

4.5

 

Electrical Installation 

IMPORTANT 

 

Refer to the electrical specifications in chapter 

3 Dimensions and Technical Specifications

 

AND the 

markings/instruction labels on the unit

. If the information differs between the data listed in the 

manual and the markings on the unit, always follow the markings on the unit.

 

 

Check and ensure that the supply voltage  and the line current  match the specifications  given on the 
rating plate. A stable mains supply must be provided. 

CAUTION 

Wrong voltage will damage the induction unit. Follow strictly 
the specifications on the rating plate. 

 

The electrical connections must satisfy the national and local electrical codes.  

 

If ground fault current protective switches are used, they must be provided with selective activation and 
designed for a minimum fault current of 30mA. Multiple generators with a mains connection must not be 
connected to a single fault current protective switch.  

To setup the unit for operation: 

1.

 

Ensure the control knob is at the OFF-Position. 

 

 

ON-Position 

Any position where 
“0”/Line is not pointing 
straight up.  

 

 

OFF-Position 

“0” / Line is pointing 
straight up. 

2.

 

Remove all objects from the glass cook-top and check that the glass cook-top is neither cracked nor 
broken. 

CAUTION

 

Do not continue if the glass cook-top is cracked or broken. 
Contact an authorized service agency for assistance. 

 

Summary of Contents for HOIN800

Page 1: ...ES 001 WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFO...

Page 2: ...NING SYMBOLS This symbol alerts you to a hazardous situation that WILL or COULD cause serious bodily harm or death Be alert and implement relevant safety precautions This dangerous voltage warning sym...

Page 3: ...Dimensions RTCSmp HOIN800 1600 2400 3200 Heat Retaining Plate 9 4 4 1 2 Cut Out Dimensions 10 4 4 1 3 Parallel Installation and Clearance 10 4 4 1 4 Installation Steps 10 4 4 2 Control Unit Installati...

Page 4: ...oundings and the induction unit Garland is not responsible for any damages or personal injury caused by failure to observe the safety requirements Risks involved when disregarding safety precautions m...

Page 5: ...The induction suitable pans should also be in good condition without any uneven arched or partially detached bottoms 1 3 Improper Use of the Equipment The reliability of the induction unit can only be...

Page 6: ...with a robust construction the RTCSmp Install Hold Line units are compact and powerful with the revolutionary RTCSmp Technology Realtime Temperature Control System with Multi Point sensing The RTCSmp...

Page 7: ...3 x 312 x 135 mm Heat Retaining Plate 20 47 x 12 60 x 2 95 520 x 320 x 75 mm Ceran Glass 20 47 x 12 60 x 0 16 520 x 320 x 4 mm 3 4 Electrical Specifications Model Voltage Power Power Per Heating Plate...

Page 8: ...unit must be installed securely in closed counters IMPORTANT Allow easy access to unit and cable connections for maintenance and service The heat retaining plate has to be mounted on a leveled and eve...

Page 9: ...tion This will force hot air out the cabinet and away from the induction unit Consult an electrical or installation expert for the most appropriate location to install a cabinet exhaust fan 4 3 Config...

Page 10: ...am in between units For other countertop materials the glass tops can be put side by side and the joints between glass tops must be water tight silicone sealed The Heat Retaining Plates can be install...

Page 11: ...seal apply silicone adhesive completely around filling any gaps between the unit and the counter top surface Carefully wipe up the excess silicone 4 4 2 Control Unit Installation The induction unit co...

Page 12: ...sures a proper grip on the knob To mount the control unit from the back of the panel 1 Drill holes on the panel using the dimensions provided 2 Remove the plastic knob from the control unit and attach...

Page 13: ...ns A Horizontally with the exhaust fan facing down B Vertically with the connectors facing up 4 4 3 2 Mounting Methods To install use the holes A and or the mounting brackets C A There are two holes o...

Page 14: ...low strictly the specifications on the rating plate The electrical connections must satisfy the national and local electrical codes If ground fault current protective switches are used they must be pr...

Page 15: ...nes Zones B D B Within each zone there are two types of connectors i coil and ii sensor Use the coil cable to connect the coil connector on the Plate to the corresponding one on the Generator Similarl...

Page 16: ...tween 122 212o F 50 100o C The digital Display underneath the Ceran glass shows the selected temperature with point eg Within 2 seconds the display shows the actual temperature and the point blinks Th...

Page 17: ...en you heat up oil or grease check the cooking process frequently to prevent the oil or grease from overheating and burning BROIL DRY PROTECTION The RTCSmp electronic temperature control monitors over...

Page 18: ...Plate of the RTCSmp HOIN800 1600 2400 3200 models is considered to be one heat zone Each heat zone is equipped with the latest RTCSmp sensor technology which enables temperature controls in realtime...

Page 19: ...rol Switch s and Induction Generator are shown HOIN800 One switch controls one heat retaining plate HOIN1600 Two switches each controls only one heat retaining plate HOIN2400 Two switches one switch c...

Page 20: ...ans when one plate is active and the temperature is shown with a blinking dot the other plates lay dormant with temperatures shown without dots This is normal However ensure you are using proper induc...

Page 21: ...f any such residues IMPORTANT Air Intake Filter We recommend using an air intake filter in your installation see section 4 2 Ventilation A dirty blocked air intake filter can cause electronic damage t...

Page 22: ...e all components relevant for safety are in perfect working order at all times Best Practice The induction unit is to be examined once a year by an authorized technician 9 Important Rules Six Simple r...

Page 23: ...hot air to re enter the induction unit through the air intake slots Dirty air intake filter Empty pans are left on the cook top when the unit is ON Symptoms When a malfunction occurs the induction un...

Page 24: ...ormal operating conditions Verify that no hot air is sucked in by the fan Reduce the ambient temperature The intake air temperature must be lower than 104 F 40 C Defective induction unit Ensure knob i...

Page 25: ...ter wiring E06 Temperature inside the generator too high T 80 C 1 Check installation Airflow E10 Reduction KK temperature T 75 C 2 Check installation Airflow E12 Reduction internal temperature T 70 C...

Page 26: ...Troubleshooting RTCSmp Built In Temperature Controlled Hold Line 26 Part 4532287 Rev 2 1 20 14 NOTES...

Page 27: ...sed correctly you will help prevent potential harm to the environment or human health which could otherwise be caused by inappropriate waste handling of this product For more detailled information reg...

Page 28: ...D LINE with RTCSmp TECHNOLOGY Garland Commercial Ranges Ltd 1177 Kamato Road Mississauga Ontario CANADA L4W 1X4 T 1 905 624 0260 F 1 905 624 5669 www garland group com USA Sales Parts and Service 1 80...

Reviews: