Installation
RTCSmp Built-In Temperature Controlled Hold-Line
Part # 4532287 Rev 2 (1/20/14)
11
To install the Heat Retaining Plate:
1.
Apply dots of silicone adhesive PACTAN (not
provide) all around the top of the step. This allows
for leveling the unit. (PACTAN part number =
70000015.)
2.
Carefully lower the Heat Retaining Plate into the
opening.
3.
Center the unit within the cut-out.
4.
Level and press the flange into the silicone at the
same time. Ensure both the countertop and the
hob(s) are leveled.
5.
To provide a water tight seal, apply silicone
adhesive completely around, filling any gaps
between the unit and the counter-top surface.
Carefully wipe up the excess silicone.
4.4.2
Control Unit Installation
The induction unit comes with up to two complete control units. The cable provided for each control is 118”
(3000mm) long. There are No Green Indicator Lights on the control units for the RTCSmp Hold-Line models.
NOTE
Install the control units
VERTICALLY
on the cabinet panel. There are two methods to install a control
unit: front-mount or back-mount onto the panel.
Installers are responsible for choosing the appropriate fasteners for the installation.
4.4.2.1
Dimensions: Control Unit RTCSmp HOIN800/1600/2400/3200
(measurements in mm and [inch])