Installation
RTCSmp Built-In Temperature Controlled Hold-Line
Part # 4532287 Rev 2 (1/20/14)
9
•
When installing the built-in unit, ensure the intake air and exhaust air are conducted separately. The in-
take air and exhaust air must not mix. To avoid build-up of hot exhaust air inside the cabinet, draw the
exhaust air out of the cabinet. Build up of hot exhaust air will cause the induction unit to reduce power
or to switch-off. The air intake temperature must not exceed 104
°
F (40
°
C).
•
We recommend drawing fresh intake air through an air intake vent with a removable air intake filter.
•
It is highly recommended that an exhaust fan be installed into the cabinet at an appropriate location.
This will force hot air out the cabinet and away from the induction unit. Consult an electrical or
installation expert for the most appropriate location to install a cabinet exhaust fan.
4.3
Configuration Options
One Induction Generator can
power up to four (4) Heat
Retaining Plates. You need to
install two (2) control units for
any configurations with 2 to 4
Heat Retaining Plates.
Configuration
Quantity - Generator
Quantity – Control Unit
1 Heat Retaining Plate
1
1
2 Heat Retaining Plates
1
2
3 Heat Retaining Plates
1
2
4 Heat Retaining Plates
1
2
4.4
Dimensions and Installation
4.4.1
Heat Retaining Plate Installation
The Heat Retaining Plate is to be flush-mounted. A support frame or support structure has to be custom designed
and built for housing the retaining plate.
4.4.1.1
Dimensions: RTCSmp HOIN800/1600/2400/3200 Heat Retaining Plate
(measurements in mm and [inch])