2.1 Technical Data
Operation and control
Lamp operation 24V DC/max. 40mA (green)
Output regulator – Potentiometer 10kOhm
Technical Data
Watts
Voltage
A) Single Table Top Units
GIU 2.5
2500
208v & 240v, 60 cycle, 1ph
GIU 2.5
2500
230v 50 cycle, 1ph
GIU 3.5
3500
208v & 240v, 60 cycle, 1ph
GIU 3.5
3500
230v, 50 cycle, 3ph
GIU 5.0
5000
208v, 60 cycle, 3ph
GIU 5.0
5000
440v, 60 cycle, 3ph
GIU 5.0
5000
400v, 50 cycle, 3ph
B) Double Table Top Units
GIU 3.5 DUAL
3500 x 2
208v, 60 cycle, 3ph
GIU 3.5 DUAL
3500 x 2
230v 50 cycle, 3ph
GIU 5.0 DUAL
5000 x 2
208v, 3ph
GIU 5.0 DUAL
5000 x 2
400v, 50 cycle, 3ph
GIU 5.0 DUAL
5000 x 2
440v, 60 cycle, 3ph
C) Table Top Wok Units
GIWOK 3.5
3500
208v &240v, 60 cycle, 1ph
GIWOK 3.5
3500
230v, 50 cycle, 1ph
GIWOK 5.0
5000
208v, 60 cycle, 3ph
GIWOK 5.0
5000
400v, 50 cycle, 3ph
GIWOK 5.0
5000
440v, 60 cycle, 3ph
Operating conditions
•
Max. tolerance of the nominal supply v6/ -10%
•
Supply frequency
50/ 60 Hz
•
Protection class
P 43
•
Minimal diameter of the pan
12 cm (5 inches)
3. Installation
3.1 Requirements of installation
The cooker has to be set up on a even place like a table. It requires an area of at least 400 x
480 mm (15.7" X 18.9"). The air inlet and air outlet must not be obstructed, the area must be
able to withstand a loading of 40 kg (88 lbs). The cooker doesn’t have to be fixed on the table.
The control knob to operate the cooker must be easily accessible.
Installation ambience
Max. ambient temperature
storage > -20° - +70° C
Function > +5° - +40°C
Max. relative humidity of air
storage > 10% - 90%
Function > 30% - 90%