REFERENCE DRAWING - E6X Option

ITEM

PART NUMBER

DESCRIPTION

T

3073856

TRANSFORMER, 575-460,  8 KVA (2T, 3T)

2FU

3104727

FUSE, CLASS CC, 600V, 12.00 A

2FB

3109441

FUSE BLOCK, 3 PL

5

1198557

CONNECTOR, CONDUIT, STRAIGHT, 1/2

QUANTITY

3058850

6

CONNECTOR, CONDUIT,  ELBOW, 1/2

2

1

1263848

9

7

3048340

ENCLOSURE

CONDUIT, SEALTITE, 1/2

1TS

GND

L3

L2

2

L1

1

CHECK MANUAL

31

32

X1

X3

X2

X4

FIELD CONNECTIONS

3TS

30

X1

X3

X2

X4

3T

2FU/2FB

2FU/2FB

H2

2T

H1

H3

34

H4

2FU/2FB

H2

H1

H3

33

H4

GND

3

575v-3ph-60hz

460v-3ph-60hz

DRYER CONNECTIONS

E6X TRANSFORMER KIT ENCLOSURE

TERMINAL BLOCK, SEGMENT

3052098

3TS

TERMINAL BLOCK END PIECE (3TS)

3117792

*

GROUND LUG

3143372

GND

14

13

12

11

NUT, HEX, PLATED, 5/16

BOLT, HEX HEAD, PLATED, 5/16-18x0.5 LG

1170745

3064064

SHIPPING SKID

PLUG, CLOSE-UP, BLACK

TBE

3090294

17

18

19

20

16

15

BOLT, HEX HEAD, PLATED, 1/4-20 x 0.5 LG

NUT, HEX, PLATED, 1/4-20

WASHER, FLAT, PLATED, 1/4

WASHER, LOCK, PLATED, 5/16

WASHER, LOCK, PLATED, 5/16

WASHER, FLAT, SAE, PLATED, 5/16

1172660

3071382

1124447

1181177

1179162

3129771

2

4

1

5

3

1

2

4

1

12

12

12

12

6

6

6

4

ENCLOSURE COVER

3091860

8

1

13

T

16

15

14

16

15

14

13

11

17 18

19 20

6

21

21

6

5

9

21

9

11

16

15

14

13

8

2FU2FB

3TS

16 15

14 13

17 18

19 20

6

21

9

23 24

0020244

3093383

3088358

3066660

12

2

1

6

24

23

22

21

BRACKET, TM-E6X

BRACKET INSERT

CONDUIT SEALING RING, 1/2

POP RIVET, 3/16

31

LABEL, "MAKE FIELD CONNECTIONS HERE"

LABEL, "DANGER, SHOCK HAZARD..."

3138598

3074098

25

26

1

1

26

25

SCREW, SL/HX/W/HD #10 AB x 1/2 LONG

3120278

28

4

4

27

3084448

NUT, TINNERMAN CLIP, #10 AB

2

29

1173312

SCREW, P/HD, MACH, 10-32 X 1/2

2

30

3137280

WASHER, FLAT, PLATED, 3/16 OR #10

2

31

1127932

WASHER, LOCK, HELICAL, PLTD, #10

2

32

3057778

NUT, HEX, PLATED, 10-32

31

29 30

32

3137200

3081543

1230514

1127939

2

2

2

2

36

33

34

35

SCREW, P/HD, MACH, 8-32 X 3/4

WASHER, FLAT, PLATED, #8

WASHER, LOCK, HELICAL, PLTD, #8

NUT, HEX, PLATED, 8-32

36

35

33 34

7

T

1

37

BULLETIN 5014

FIELD INSTALLATION INSTRUCTIONS BULLETIN

GND

GND

17 18

19

17

18

19

SHIPPING CARTON

3106651

*

1

15 16

14

13

2FU

2FU

T

TRANSFORMER, 575-460, 12 KVA (2T, 3T)

1283599

3125760

1270049

FUSE, CLASS CC, 600V, 17.50 A

FUSE, CLASS CC, 600V, 15.00 A

5

21

Ø0.375 MOUNTING HOLES

8 PLACES

CORNER POST

3.63

15.25

29.12

44.38

3

3

3

2

3094394 (800)

3065280 (1000)

3110989 (1200)

Summary of Contents for RCD800

Page 1: ...050414 CONTENTS INTRODUCTION 2 SAFETY 2 SAFETY INSTRUCTIONS 3 RECEIVING AND INSPECTION 3 INSTALLATION 3 HOW IT WORKS 5 ENERGY MANAGEMENT CONTROLLER EMC 7 EMC MEMBRANE PANEL 8 AUTOMATIC DRAIN VALVES AD...

Page 2: ...der pressure within the dryer can cause severe injury or death 4 High voltage in the motor and control box is danger ous The dryer must be installed in accordance with recognized electrical codes Befo...

Page 3: ...m filing and processing is your responsibility Handling The dryer is mounted on a base to facilitate moving the dryer with a forklift Forks should extend all the way through the forklift channels prov...

Page 4: ...cause a rise in dew point unless the dryer inlet air flow is reduced The refrigerant discharge pressure control will shut down the refrigerant compressor if cooling water is inadequate Table 2 COOLING...

Page 5: ...es CAUTION Operation of dryers with improper line voltage con stitutes abuse and could affect the dryer warranty Standard dryer enclosures and controls are designed to meet NEMA Type 1 electrical stan...

Page 6: ...CUT OUT SWITCH AMBIENT AIRFLOW CONDENSER DISCHARGE COMPRESSOR SUCTION SERVICE ACCESS VALVE HPS GLYCOL TANK GLYCOL MIXTURE SEPARATOR DRAIN SUCTION COMPRESSOR DISCHARGE CONDENSER WATER OUT WATER IN WAT...

Page 7: ...l e D r e y r D e t u n i m 1 o t 0 s d n o c e s 0 6 s e t u n i m 0 6 o t 1 y a l e d o N s t r a t s e r r e y r d y l e t a i d e m m i s r u o h 4 o t 1 s r u o h 4 o t 1 p u m r a w l l i w r e...

Page 8: ...he dryer i e the Dryer On LED is off Up and Down Buttons Used to change the display for the right hand column of LEDs when the DISPLAY SELECT button is pressed These buttons are also used to select th...

Page 9: ...setting the drain open times Drain Closed LED Indicates when the automatic drain valve is closed See Set Auto Drain Off Time Min for information on setting the drain closed times Fahrenheit LED Indic...

Page 10: ...ff time Press the DISPLAY SELECT button until the Set Auto Drain Off Time Min LED is lit The display will show the current drain off time setting in minutes Press the up or down button to increase or...

Page 11: ...rn on at the proper time refer to the Maintenance section of this manual If the dryer is under warranty call your local distributor for authorization before servicing To minimize air losses set the ti...

Page 12: ...equire little maintenance for satisfactory operation Good dryer performance can be ex pected if the following routine maintenance steps are taken DANGER Dismantling or working on any component of the...

Page 13: ...or blow out debris with compressed air from an OSHA approved air nozzle that limits its discharge pressure to 30 psig 12 Check that small port in diaphragm assembly is clear and solenoid coil moves fr...

Page 14: ...I e g r a h e r d n a r i a p e r k a e l e t a c o L y r o t c a f t l u s n o c d e c a l p e r n o i t c u s t n a r e g i r f e R n a h t r e h g i h e r u t a r e p m e t l a m r o n F 0 2 1 n a...

Page 15: ...ype Valve Aids in Disconnecting Compressor from the System PRESSURE GUAGE THERMOMETER DRIP LEG MANOMETER DIFFERENTIAL PRESSURE INDICATOR AUTOMATIC DRAIN VALVE FALSE LOADER Blows Off Air Outside of Com...

Page 16: ...7 2 1 7 0 1 4 6 5 1 2 2 2 3 5 9 7 0 1 2 0 0 2 1 3 7 8 1 5 7 3 7 0 1 8 1 5 2 1 7 8 7 9 5 8 3 5 7 7 1 9 8 9 6 2 7 2 1 7 0 1 8 5 5 6 9 1 2 6 0 0 1 3 2 2 2 NOTE Dimensions and weights are for reference o...

Page 17: ...oltage 460 3 60 Max Min voltage 506 414 Rated Load Amps 7 69 9 62 9 94 Locked Rotor Amps 42 67 80 Minimum Circuit Ampacity 11 69 14 21 14 82 Branch Circuit Fuse Size amps 17 5 20 20 Watts 35 F Evapora...

Page 18: ...18 REPLACEMENT PARTS Air Cooled Models 800 1200 scfm 1 6 7D 7C 9 3 4 5 7A 7B 6 8 2 7A 7B REAR VIEW TOP VIEW FRONT VIEW LEFT SIDE VIEW...

Page 19: ...G 4 0 5 9 9 0 3 G 0 8 5 8 6 0 3 G r o t i c a p a C n u R r o t o M n a F 1 9 0 1 5 0 3 G 1 9 0 1 5 0 3 G 8 5 9 2 6 0 3 G 6 0 6 3 0 6 4 r o s s e r p m o C 0 5 2 6 3 1 3 G 0 4 6 0 1 1 3 G 9 7 1 9 9 0...

Page 20: ...20 REPLACEMENT PARTS Water Cooled Models 800 1200 scfm FRONT VIEW TOP VIEW LEFT SIDE VIEW REAR VIEW 3 1 2 9 5 8 6 4 7D 7C 7A 7B 7A 7B...

Page 21: ...3 G r o t c a t n o C r o s s e r p m o C 9 2 6 6 3 1 3 G 9 2 6 6 3 1 3 G 9 2 6 6 3 1 3 G t i K r e m r o f s n a r T 4 9 3 4 9 0 3 G G 0 8 2 5 6 0 3 9 8 9 0 1 1 3 G y l b m e s s A w o l F r i A A 7...

Page 22: ...SIC TMR 1 2 3 POWER 21 J5 22 20 J4 NO ALARM CONTACTS NO NC GND EMERGENCY STOP SWITCH COMPRESSOR FAN1 1 2 3 HIGH PRESSURE CUT OUT WITH MANUAL RESET HPS M 32 RC DRAIN VALVE RATING 5A 115 VAC 5A 24 VDC 1...

Page 23: ...ER 2 1 IDP DIP SWITCHES 1 2 3 SEE NOTE 14 6 5 8 7 COMPRESSOR 1 1 2 CUTOUT SW J8 2 DRAIN VALVE J7 1 2 3 4 1 2 3 J6 ALARM J5 C OPTION DRAIN VALVE 1 TMR 20 20 3TS 21 2SOL POWER J4 CHASSIS GROUND 5A 24 VD...

Page 24: ...2 2 1 1 2 CONTROLLER 2 1 IDP DIP SWITCHES 1 2 3 SEE NOTE 14 6 5 8 7 COMPRESSOR 1 1 2 CUTOUT SW J8 2 DRAIN VALVE J7 1 2 3 4 1 2 3 J6 ALARM J5 DRAIN VALVE 1 TMR 20 20 3TS 21 2SOL POWER J4 CHASSIS GROUN...

Page 25: ...1 2 4 1 5 3 1 2 4 1 12 12 12 12 6 6 6 4 ENCLOSURE COVER 3091860 8 1 13 T 16 15 14 16 15 14 13 11 17 18 19 20 6 21 21 6 5 9 21 9 11 16 15 14 13 8 2FU2FB 3TS 16 15 14 13 17 18 19 20 6 21 9 23 24 0020244...

Page 26: ...y a l p s i D e t a D e m i T y B n i a r D o t u A e v l a V l i O p m o C l e v e L n O r e w o P h g i H e r u t a r e p m e T m r a l A w o L e r u t a r e p m e T m r a l A s s e c o r P s l o r...

Page 27: ...27 NOTES...

Page 28: ...SLY IN LIEU OF THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WAR RANTY OF FITNESS FOR A PARTICULAR PURPOSE THE MANUFACTURER SHALL NOT BE LIABLE FOR LOSS OR DAM AGE BY REASON OF STRICT LIABIL...

Reviews: