RB-7-100 Page 13
Exceeding overhung load limitations leads to unwarrantable premature bearing failure and shaft
breakage.
The location of the sheave on the blower shaft greatly affects the stress in the shaft. The optimum blower sheave
positioning is as close as possible to the blower drive cover.
The calculated shaft load must not exceed the maximum allowable load listed in Maximum Belt Load Chart,
FIGURE 2-2. If the calculated shaft load exceed the maximum allowable load:
Increase Sheave Diameters to Reduce Belt Pull
Use Jackshaft Drive
Use Direct Coupled or Gearbox Drive
To calculate shaft load for a given V-Belt Drive Arrangement:
Insert the belt pull into the formula for Calculation of Shaft load, FIGURE 2-2, to arrive at the calculated
shaft load.
PIPING
Inlet and discharge connections on all blowers are large enough to handle maximum volume with minimum
friction loss. Reducing the pipe diameter on either inlet or discharge will only create additional line loss and
increase the overall pressure differential. Excessive weight of piping and fittings will cause internal misalignment
and premature wear. Never allow the blower to carry the weight of the pipe. If possible, a spool or sleeve-type
expansion joint should be installed between the unit and the piping. Where a flexible connection is not practical,
the weight of the rigid connection must be separately supported.
All system piping must be cleaned internally before connecting to the blower.
RBS blowers are shipped dry from the factory. Do not attempt to operate the blower before
following proper lubrication instructions. Permanent damage to the gears, bearings and seals will
occur.
Summary of Contents for RBS 15
Page 2: ......
Page 16: ...RB 7 100 Page 15 RBS OVERHUNG LOAD...
Page 26: ...RB 7 100 Page 25 SECTION 5 MAINTENANCE FIGURE 5 1 MAINTENANCE CHECK LIST...
Page 29: ...RB 7 100 Page 28 SECTION 7 PARTS LIST 7 1 RBS 15 25 Sectional drawing FIGURE 7 1...
Page 31: ...RB 7 100 Page 30 7 2 RBS 35 106 Sectional drawing FIGURE 7 2...
Page 34: ...RB 7 100 Page 33 7 3 RBS 115 225 Sectional drawing FIGURE 7 3...
Page 37: ...RB 7 100 Page 36 OVERHAUL KIT...
Page 38: ...RB 7 100 Page 37...
Page 39: ...RB 7 100 Page 38...
Page 41: ......