10.13
Maintenance notes and lubricant
recommendations for stationary
compressors
Lubricant recommendations
Please note that proper lubrication can significantly
increase the lifespan of your compressor system.
In accordance with valid accident prevention
regulations, lubricating oils should be used whose
characteristics correspond to the expected operating
conditions.
Avoid mixing different lubricating oils, i.e. when
changing the oil type, first completely drain the old oil
from the oil circuit.
If seal temperatures are constantly above 195 °F divide
the oil change intervals given in Section 10.3
(Maintenance schedule) by half.
The exact oil change schedule according to the actual
operating conditions should be set by performing oil
tests.
Material Safety Data Sheets (MSDS) are available for
all Gardner Denver lubricants from your authorized
Gardner Denver distributor or by calling Gardner
Denver-USA at (937) 498-2500.
The following oil types should be used
a) AEON 9000SP
For further information, please contact your local
Gardner Denver Distributor or Gardner Denver-USA at
(937) 498-2500.
10.14
Test period for pressure reservoir
and electrical installation
Pressure reservoir
After five years a qualified individual must check the
pressure reservoir from the inside in accordance with
97/23/EG regulations.
After ten years a named location must carry out a
strength test on the pressure reservoir in accordance
with 97/23/EG regulations.
Electrical installation
After four years, or after each intervention, the electric
installation must be tested by an electrician.
If shorter testing periods are required in your country,
then these should be used.