7 Preparation for Commissioning
28
7.3
Electrical connection
(only USA/CANADA version)
DANGER
Risk of strong damage and fire on the
electric power components.
•
The power supply to the compressor
side has to be fitted for industrial
equipment and fulfilling the
requirements of NFPA 79. Any kind of
operation outside of the stated limits of
NFPA 79 is inadmissible.
•
The electrical connection should be
made by a qualified electrician.
DANGER
Only for L23RS-L29RS: There is a risk of
electric shock from charged capacitors!
•
Disconnect the system from the mains
and wait 10 minutes before touching
electrical components. The power
capacitors need this time to discharge.
Make electrical connections as follows:
Feed the supply cable through the opening (-M50- Fig. 13)
in the switch cabinet and screw tight.
Connect the supply cable to the connection terminal
following the circuit diagram.
Fig. 13
CAUTION
If local regulations are stricter than the
values given below, the stricter of the two
should be used.
Recommended supply cable diameters and fuses
Compressor Type
Supply Voltage
[V]
Installed
Nominal Motor
Rating
[hp]
Fuse protection
(time delay fuse)
[AgG]
Cable type
167°F /
Copper
60 Hz Compressors
L23
200V
230V
460V
575V
29.5
110
90
50
40
AWG 1*
AWG 2*
AWG 6*
AWG 8*
L23RS
460V
29.5
50
AWG 6*
L26
200V
230V
460V
575V
34.9
125
110
60
50
AWG 1 / 0*
AWG 1*
AWG 6*
AWG 8*
L26RS
460V
34.9
63
AWG 6*
L29
200V
230V
460V
575V
40.2
150
125
70
50
AWG 2 / 0*
AWG 1 / 0*
AWG 4*
AWG 6*
L29RS
460V
40.2
63
AWG 4*