13–8–609 Page 12
greasing intervals for ball bearing motors. For addition-
al information refer to the motor manufacturer’s
instructions. The following procedure should be used
in regreasing:
1.
Stop the unit.
2.
Disconnect, tag and lockout the unit from the pow-
er supply.
3.
Remove the relief plug and free hole of hardened
grease.
4.
Wipe lubrication fitting clean and add grease with
a hand–operated grease gun.
5.
Leave the relief plug temporarily off. Reconnect
unit and run for about 20 minutes to expel the ex-
cess grease.
6.
Stop the unit. Replace the relief plug.
7.
Restart the unit.
Rotating machinery can cause injury
or death. Open main disconnect, tag
and lockout power supply to the start-
er before working on the electric mo-
tor.
ELECTRIC MOTOR GREASE RECOMMENDATIONS (–30
_
to 50
_
C)
MANUFACTURER
TRADE NAME
CHEVRON
SRI #2
SHELL
DOLIUM R
EXXON
UNIREX #2
EXXON
POLYREX
ELECTRIC MOTOR REGREASING INTERVAL
Type of Service
Typical Examples
Rating
Relubrication Interval
Standard
One– or Two–Shift Operation
150 HP (112 KW)
18 Months
& Below
Severe
Continuous Operation
150 HP (112 KW)
9 Months
& Below
Very Severe
Dirty Locations, High
150 HP (112 KW)
4 Months
Ambient Temperature
& Below
Summary of Contents for ELECTRA-SCREW EBE DH-15 HP
Page 14: ...13 8 609 Page 6 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Page 15: ...13 8 609 Page 7 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Page 32: ...13 8 609 Page 24 FIGURE 4 10 WIRING DIAGRAM DUAL CONTROL 218EBE546 Ref Drawing...
Page 33: ...13 8 609 Page 25 FIGURE 4 11 WIRING DIAGRAM WYE DELTA 220EBE546 Ref Drawing...
Page 51: ......