background image

5. MAINTENANCE

The pumps are virtually maintenance-free.

Flushing the Pump:
After having pumped chlorinated swimming pool water or 

other liquids leaving residues, the pump should be rinsed 

with clear water.

Cleaning the suction base and impeller [ Fig. M1]:

  

DANGER! Electric shock!

 

 Risk of injury due to electric shock.

v  

Disconnect the pump from the mains before 

cleaning the suction base and impeller.

1.  Unscrew the 6 Phillips screws 

9

 and pull the suction 

base 

0

 off the pump.

2.  Clean suction base 

0

 and impeller 

q

 (the warranty 

does not become void as a result of this maintenance 

work).

3.  Reinstall the suction base 

0

 and screw in the Phillips 

screws 

9

.

For safety reasons a damaged impeller 

q

 can only 

be exchanged by the GARDENA Service Centre.

Clean sensors [ Fig. M2]:

The sensors will only work reliably if they are 

cleaned regularly (at least every 2 months)!

v

  Clean the sensors 

4

 and contact 

7

 regularly with  

a dry cloth (do not use hard or sharp objects).

4. STORAGE

To put into storage:

v

  Store the pump away from frost before the first frost 

sets in.

Disposal: 

(in accordance with RL2012/19/EC)

The product must not be disposed of to normal 

household waste. It must be disposed of in line with  

local environmental regulations.

IMPORTANT!
Dispose of the product through or via your municipal 

recycling collection centre.

6. TROUBLESHOOTING

Problem

Possible Cause

Remedy

Pump is running,  

but doesn’t deliver

Air cannot escape.

v

  Open pressure line (e. g. kinked 

pressure pipe).

v

 Remove the non-return valve.

Non-return valve inserted wrongly.

v

  Insert the non-return valve with the 

word UP on top.

Air locks in the suction base.

v

  Wait for max. 60 seconds until the 

pump deaerates automatically over 

the vent valve. If necessary, switch 

off and start it again.

Impeller clogged.

v

  Disconnect plug and clean impeller 

(see 5. MAINTENANCE).

When starting the pump, water height 

falls below the min. water level.

v

 Submerge pump deeper.

The pump does not switch on  

or off. Pump switches off although 

the OFF sensor is in the water

Sensors 

4

 and contacts 

7

 are 

dirty.

v

  Clean sensors  

(see 5. MAINTENANCE).

Pump doesn’t start or suddenly  

stops during operation

Thermal overload switch has  

switched the pump off due to 

 overheating.

v

  Disconnect plug and clean impeller 

(see 5. MAINTENANCE). 

Observe max. media temperature  

of 35 °C.

No power.

v

  Check fuses and electric connec-

tions.

EN

13

Summary of Contents for 9000 aquasensor

Page 1: ...PL Instrukcja obs ugi Pompa zanurzeniowa Pompa do brudnej wody HU Haszn lati utas t s Mer l szivatty Szennyv zszivatty CS N vod k obsluze Ponorn erpadlo kalov erpadlo SK N vod na obsluhu Ponorn erpadl...

Page 2: ...S1 1 I1 2 y I2 I3 I4 I5 2 V O1 6 3 4 5 O2 4 3 O3 6 3 4 5 O4 3 4 7 O6 O7 O5 8 M1 0 q 9 9 M2 3 4 7 3...

Page 3: ...ON The GARDENA Pumps are not designed for continuous operation e g continuous circulating operation in a pond Your pump s life will be short ened correspondingly by such operation Corrosive easily com...

Page 4: ...ump s output Take care that the pump is located where the inlet open ings at the suction base are obstructed neither completely nor partly Stand the pump on a brick if using in a pond Leaking lubrican...

Page 5: ...the pump in a well or shaft 3 Plug the power cable 6 into a mains socket Only for the submersible pumps Flat suction Normal operation Fig O5 Flat suction Fig O6 v Turn the 3 swivel feet 8 180 to 1 mm...

Page 6: ...ith RL2012 19 EC The product must not be disposed of to normal household waste It must be disposed of in line with local environmental regulations IMPORTANT Dispose of the product through or via your...

Page 7: ...livery capacity bar 0 7 0 8 0 6 0 9 Max pressure m 7 8 6 9 Max delivery height m 7 7 7 7 Max submersion depth mm 1 1 35 35 Contaminated water with particle size of max mm 5 5 30 30 Power cable m 10 H0...

Page 8: ...ect to the fol lowing provisions The product was used for its intended purpose as per the recommendations in the operating instructions Neither the purchaser nor a third party has attempted to repair...

Page 9: ...akteristika erpadla Charakteristiky erpadla Karakteristika rpalka Obilje ja pumpe Karakteristika pumpe Caracteristic pomp Pompa karakter e risi Fuqia e pomp s Pumba karakteristik Siurblio charakterist...

Page 10: ...ke p tager os noget ansvar for skader p vores produkter hvis de p g ldende produkter ikke er blevet repareret korrekt af en GARDENA godkendt servicepartner eller hvor der ikke er brugt originale GARDE...

Page 11: ...jujemo kako ne prihva amo nikakvu odgovornost za o te enja na na im proizvodima nastala uslijed neispravnog popravka od strane servisnog partnera kojeg odobrava GARDENA ili uslijed nekori tenja origin...

Page 12: ...a est o em conformidade com as diretrizes uniformizadas da UE os padr es de seguran a da UE e os padr es espec ficos do produto Este certificado deixa de ser v lido se as unidades forem modificadas se...

Page 13: ...aci n del distintivo CE Ano de marca o pela CE Rok nadania oznakowania CE CE jelz s elhelyez s nek ve Rok um st n zna ky CE Rok udelenia zna ky CE CE Leto namestitve CE oznake Godina dobivanja CE ozna...

Page 14: ...a husqvarna co uk Italy Husqvarna Italia S p A Via Santa Vecchia 15 23868 VALMADRERA LC Phone 39 0341 203 111 assistenza italia it husqvarna com Japan KAKUICHI Co Ltd Sumitomo Realty Development Kojim...

Reviews: