Problem
Possible Cause
Remedy
Pump doesn’t start or suddenly
stops during operation
Dirt particles are jammed in the
suction base.
v
Disconnect plug and clean suction
base (see 5. MAINTENANCE).
Pump runs, but output suddenly
decreases
Suction base is clogged.
v
Disconnect plug and clean suction
base (see 5. MAINTENANCE).
NOTE: For any other malfunctions please contact the GARDENA service department.
Repairs must only be done by GARDENA service departments or specialist dealers approved
by GARDENA.
7. TECHNICAL DATA
Submersible pumps
aquasensor
Dirty water pumps
aquasensor
Unit
Value 9000
(Art. 1783)
Value 13000
(Art. 1785)
Value 8500
(Art. 1797)
Value 13000
(Art. 1799)
Rated Power
W
320
650
380
680
Rated power
l/h
9,000
13,000
8,300
13,000
Max. delivery capacity
bar
0.7
0.8
0.6
0.9
Max. pressure
m
7
8
6
9
Max. delivery height
m
7
7
7
7
Max. submersion depth
mm
1
1
35
35
Contaminated water with
particle size of max.
mm
5
5
30
30
Power cable
m
10 H05RN-F
10 H07RN-F
10 H05RN-F
10 H07RN-F
Pump connection
universal (G 1 ¹⁄₄" M) / universal nipple
Min. water level for operation
mm
5
5
45
45
Weight approx. (without cable)
kg
3.8
5.4
4.0
5.6
Max. media temperature
°C
35
35
35
35
Mains voltage / Mains frequency
V / Hz
230 / 50
230 / 50
230 / 50
230 / 50
Min./max. cut-in height
mm
5 / 175
5 / 210
65 / 230
70 / 265
Min./max. cut-out height
mm
3 / 170
3 / 205
40 / 225
40 / 260
Sound power level L
WA
1)
dB (A)
48
55
55
55
Measuring process complying with:
1)
EN 60335-1
Cut-in / Cut-out height:
The cut-in and cut-out height varies.
Only for the submersible pumps Art. 1783 / 1785:
The residual water height (flat suction down to approx.
1 mm) is only reached during manual operation with the
swivel feet
8
turned to 1 mm (see 3. OPERATION).