8.1
PP602F CCS connectors
PP602F controllers are additionally fitted with connectors for CCS lights.
Note that the power input and digital inputs are only available on the screw
terminals.
The connectors are not labelled on the case. Refer to the table and the
diagram below for the layout.
Connector
Channel
Use
SKT9
1
CCS 12V lights
SKT10
1
CCS 24V and HLV lights
SKT12
2
CCS 12V lights
SKT11
2
CCS 24V and HLV lights
12V lights always have a 2 pin connector, 24V and HLV lights always have
a 3 pin connector.
The CCS lights are labelled with a voltage and wattage rating, but PP602F
controllers produce a constant current supply at their outputs. To
—
20
—