PP600F/602F LED lighting controllers - User Manual
condition is approximately given by the sum of the following for the two
channels:
(V
PS
-V
L
) x I
PS
Where:
V
PS
= Power supply voltage
V
L
= Rated voltage for lighting
I
PS
= Maximum current delivered by the power supply.
Either limit the power supply output current(s) so that not more than 30W
can be dissipated in the PP600F, or mount the unit in an enclosure.
For further information about heat output from the PP600F, refer to
To limit the power, set the power supply output voltages to the minimum
value required by the LED light and the PP600F together. Chose a PSU
that limits its output current by design, by setting the current limit on the
supply (if this feature exists) or use fuses. Remember to de-rate the fuse if
mounted in an enclosure, as the temperature will be higher than ambient.
An enclosure may also be required for other parts of the system such as
power supplies and should provide mechanical and environmental
protection in industrial applications.
If an enclosure is used, it should be metal or plastic (with a flammability
rating of UL94-V1 or better) and with no holes below or to the sides of the
PP600F when mounted. Cable entries below the PP600F should be
through glands that also have a flammability rating of UL94-V1 or better.
Observe the specified gap between the PP600F and any other part or side
of the enclosure.
—
16
—