Camera Calibration
63
Step 2: Adjust tilt angle and camera height
Now, adjust the camera tilt angle and vertical field of view until both mimics are
approximately the same size as a real person at that position in the scene. If an estimated
height is entered then adjust this along with the other two parameters.
Click and drag the ground plane to change the tilt angle, use the mouse wheel to adjust the
camera height and drag the slider to change the vertical field of view.
The 3 calibration parameters will be reflected in the edit boxes in the Camera Setup section
of the web page.
Apply the changes:
Once the changes have been applied, the Calibration Status reflects whether the operation
was successful, and if so, in which mode the camera is calibrated.
Step 3: Verify the setup