SYSTEM SETUP
EVENT / SENSOR - ALARM OUT
Click on the
ALARM OUTPUT
menu, and click on a field.
Use the button to modify the value.
This menu will determine the behavior and actions that will trigger each of the 1 alarm output.
Behavior settings
ALARM OUT
: Choose which alarm output to configure.
OPERATION
: The selected alarm output can be enabled or disabled.
MODE
: Can be either set as ‘TRANSPARENT’ (the output is active only when the trigger criteria is present)
or ‘LATCHED’ (the output is active for a set period of time after the trigger).
DURATION
: In ‘LATCHED’ mode, the amount of time that the alarm output remains active after it has been triggered.
TYPE
: Can be set to high (0V to +5V when activated) or low (+5V to 0V when activated).
HDD EVENT
: Determines whether a hard drive event will trigger an alarm output.
Action settings
ALARM
: Determines whether the specific channel alarm input would trigger the alarm output.
VIDEO LOSS
: Determines whether video loss on any of the selected channels will trigger the alarm output.
MOTION
: Determines whether motion detection on any of the selected channels will trigger the alarm output.
NOTE:
Remember to select ‘
APPLY
’ and press ‘
ENTER