Installation
5
· G&D DVI-Vision-CAT
Installation
Preparation
1. Ensure that the computer to be connected to the computer module is switched
off. If the computer is provided with keyboard and mouse, unplug the cables of
the input devices from the interfaces.
2. Place the computer module (
DVI-Vision-CAT-CPU
) close to the computer.
3. Place the user module (
DVI-Vision-CAT-CON
) close to the remote console.
4. Take the supplied cables and have them ready for the installation of the devices.
IMPORTANT:
When choosing a location for the devices, please ensure to comply
with the ambient temperature limit (see
on page 55 ff.) close to the
device. The ambient temperature limit must not be influenced by other devices.
When installing the devices, make sure to only place a maximum of three devices
directly on top of each other. This way, a good circulation of air is provided and
mutual thermal interference can be avoided. After having installed three devices,
provide for a distance (at least 2 cm).
IMPORTANT:
Do not cover the ventilation openings. For reasons of electric safety,
mount device variants pthat provide ventilation openings only horizontally.
Please refrain from using devices with ventilation openings in dusty environ-
ments. Dust in the housing can damage the electronics and may cause failures.
NOTE:
Please mind the maximum cable length of
five
meters between the com-
puter module and the computer to be connected.
NOTE:
Please mind the maximum cable length of
five
meters between the user
module and the devices of the user console.