Chapter 6: Adding a new Load/Power Supply to Framework
6-7
[IRangeX]
The
[IRangeX]
section provides information about the current ranges for the power device in use. Depending
on the number of available current ranges, one or more IRange sections for the power device are required. The
number of sections has to match the number of current ranges for the power device. The range number
X
starts at
0 and can go up to a maximum of 3. Hence a maximum of 4 current ranges is possible. The ranges should be
entered in ascending order, so the smallest and first range is
IRange0
. The example below depicts the
information for a BP4610 power supply from NF Corporation which has a single 10 A current range. Each of the
keys for this section will be discussed below.
[IRange0]
RangeMaxI= 10.0
RangeMaxVin= 10.0
RangeMaxVout = 1.0
RangeMaxFreq= 30000.0