![background image](http://html1.mh-extra.com/html/gama/easy-spray-h/easy-spray-h_service-manual_3308459010.webp)
Easy Spray-H
Service manual
10/48
Issue 1.9
Ref. NR-00088-ENG
http://www.gamapur.com/
22. Hydraulic oil tank
Contains the oil used by the unit’s hydraulic system.
23. Hydraulic cylinder
Drives the pumps.
24. Oil level and thermometer
Displays the fluid level and temperature of the hydraulic oil tank.
25. Electric motor
Drives the hydraulic pump.
26. Hydraulic pump
Axial piston pumps are swash plate design variable displacement pumps.
The flow and pressure compensator control, also known as a load sensing control, matches
pump output flow and pressure to the system demand.
Pumps oil to the hydraulic cylinder.
27. Hydraulic return filter
Filters impurities from the hydraulic oil.
28. Hydraulic oil fill cap
For topping up the oil tank.
29. Heated hose sensor switch
Enables control of the temperature in the hoses.
30. TCS DIP switches
Enables selection of the hose heater control mode depending on
whether hoses incorporate a temperature control sensor (TCS).
See page 11 point 2 of this manual for instructions on selecting the
correct control mode.
The unit must be disconnected before
operating the DIP switch.
31. Temperature units DIP switch
Enables selection of temperature units on the control panel
displays. Set this switch to the “EU” position to display the
temperature in
degrees Celsius (ºC), or “USA” to display the
temperature in degrees Fahrenheit.
The unit must be disconnected before operating the
DIP switch.
32. Motor DIP switch
Activates/deactivates the hydraulic drive. Factory settings depend
on the model.
The “Motor DIP” selector function is only active
in units with hydraulic drive.
The unit must be disconnected
before operating the DIP switch.