Easy Spray-H
Service Manual
23/48
Issue 1.9
Ref. NR-00088-ENG
http://www.gamapur.com/
e)
Insert a contact thermometer under the hose’s outer sheath so that the lower part of the
thermometer is in contact with the hoses and the upper part projects from the hose’s
outer sheath. Position the thermometer in such a way that you can see the temperature
while spraying. With hoses incorporating a temperature control sensor there is no need
to fit a contact thermometer.
f) Fill the tanks with their respective product.
WARNING!
When handling chemical products, always follow the supplier’s safety and storage
instructions.
To prevent splash contamination between one tank and the other, open only the cap of
the tank being filled with product.
Never swap parts between one tank and the other, and always use the same tank for the
same product.
WARNING!
To prevent cross-contamination of products, make sure the tanks are properly closed.
To avoid spillage during transportation of the unit, never fill the tanks completely: always
leave about 20% of the tank capacity free (each tank holds 30 litres).
We recommend using small vessels (10-15 litres maximum) for pouring product into the
tanks.
Fill the tanks with the amount of product required for each application.
Purge method for heated hoses
Before using the unit, all air pockets and residual oil from in-factory testing must be eliminated.
To purge the full circuit, proceed as follows:
a) Open the manual purge valves located under each tank.
b) Place the coupling block so that each
product
drains
into
a
separate
recipient and open the manual valves
of each product.
c) Rotate the power switch to the ON
position. The upper pilot light goes on.
d) Press the CONTROL/POWER button.
The LED will light up.