To join hoses to each other, to the heaters, or to the gun, hold each hose
end in place with a spanner (1), and with a third spanner tighten or loosen the coupling
nut (2) as required (see Figure 3 18.
These couplers should be tightened to a torque of 20
Nm.
c) Put 18 li
tres of hydraulic oil in the unit’s oil tank. The oil should comply with the
characteristics and specifications of standard DIN 51524 sections 1 and 2 (for example
ISO VG 46).
NOTE:
Do not fill the tank to its maximum capacity (22
litres); the oil level should not exceed 85% of the maximum
capacity (18 litres
approx.).
Use the visor of the oil
thermometer to check the oil level, as this should always be
completely full (18 litres).
d) Check the oil level in the hydraulic pump by removing
the drain coupler from the pump and making sure the oil
level reaches the top of the filler neck. Add oil if
necessary and reconnect the coupler.
Preparation (units with recirculation hose)
WARNING!
Use suitable protective gear and follow the safety recommendations of the
suppliers of the chemical components when preparing or working with the unit.
NOTE:
To ensure the correct operation of the unit, the electrical power supply must
meet the specifications given on p 6 of this manual and on th
e unit’s rating plate.
After following steps a), b), c) and d) of the preparation procedure (see
p.18
), follow the
procedure given below to prepare the unit for recirculation:
a) Connect the recirculation hose of each product to the recirculation valves located in the
respective product tanks (the
isocyanate
hose
to
the
isocyanate tank valve and the
polyol hose to the polyol tank
valve).