MAINTENANCE 

FILTER CLEANING INSTRUCTIONS 

This faucet is provided with a stainless-steel filter to prevent foreign particles entering the tap. If the water flow 
has decreased, this may be because the filter is clogged. The filter can be cleaned as follows: 

 

 
 
 
 
 

 
 
 
                                                              

1. Disassemble: 

 

Shut-off the water supply to the valve. 

 

Release the set screw at the faucet body by using the 2.5 mm Allen Key.  

 

Disassemble the faucet’s body from the base. 

 
 
 
 

 
 
 
 
 
2. Clean filter: 

 

Disassemble the filter from the base.

 

 

Wash the filter under running water. 

 

 

Fit the filter.

 

  

 
 

 
 
 
 
 
 
 
3. Assemble: 

 

Slide the flange and the faucet onto the inlet tail. 

 

Mount the faucet body onto the inlet tail. Ensure 
the sensor is aligned facing down. Secure the 
body with M5 grub screw using the supplied 
Allen key. 

AERATOR CLEANING INSTRUCTIONS 

  
 
 
 
 

1. 

Disassemble and Clean

 

Using an adjustable spanner, unscrew the 
aerator holder. 

 

Wash the aerator under running water.  

 
 
 
 
 

2. Assemble: 

 

Once cleaned, fit cleaned aerator back into the 
holder. 

 

Using the adjustable spanner, tighten the aerator 
holder back into the body. 

CARE AND CLEANING OF CHROME AND SPECIAL FINISHES 

DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or

 

the like. Use of any 

prohibited cleaning or maintenance products or substances

 

could damage the surface of the faucet. For 

surface cleaning of faucet, use ONLY soap

 

and water, then wipe dry with clean cloth or towel. When cleaning 

bathroom tile, the

 

faucets should be protected from any splattering of harsh cleansers.

 

Summary of Contents for Flowmatic TZ-FLOW225866

Page 1: ...Customizable settings by optional remote control sensor range security time delay In delay out and on off 24 hours mandatory hygiene flush option available upon request Chrome plated assembly for dura...

Page 2: ...reflective material such as stainless steel 3 If a sink strainer is straight below the faucet sensor use a strainer with a non reflective finish do not use a chrome plated one PREPARATION FOR INSTALLA...

Page 3: ...er supply Thread tape sealant should be used Ensure the thread tape doesn t obscure the inlet tail opening Connect inlet tail to water inlet Tighten inlet tail ensuring it cannot be turned once instal...

Page 4: ...ol hold the remote control straight in front of the sensor at a distance of about 6 8 15 20cm Choose the function you want to adjust by pressing once on one of the function buttons After pressing once...

Page 5: ...n is ideal to perform any kind of activity in front of the sensor without operating the system for example cleaning The product will remain shut for 1 minute when this button is pressed once To cancel...

Page 6: ...sensor cap carefully Verify that the O ring on the sensor head and water is in good condition If needed apply grease or replace it with 1 5mm x 38mm O ring 3 Replacing the battery Remove the old batte...

Page 7: ...to the inlet tail Ensure the sensor is aligned facing down Secure the body with M5 grub screw using the supplied Allen key AERATOR CLEANING INSTRUCTIONS 1 Disassemble and Clean Using an adjustable spa...

Page 8: ...nsor flashes once when user s hands are within the sensor s range The water supply pressure is higher than 500 kPa Reduce the supply water pressure Water flow from spout does not stop 1 Led in the sen...

Page 9: ...rer s warranty During the warranty period Galvin Engineering will replace or repair any defective products manufactured by Galvin Engineering without charge so long as the terms of the Manufacturer s...

Reviews: