BATTERY REPLACEMENT 

Low battery indicator 

When the battery requires replacement

, the LED indicator light will blink at a constant rate when the user’s hands 

are within the sensor range. The battery must be replaced, as follows: 

 

 

1. Disassemble: 

 

Turn off the water supply.  

 

To access the battery, unscrew the set screw located 
at the underside part of the body using the 2mm 
Allen key (supplied with the kit) 

 

 

2. Pull out sensor head: 

 

Pull out the sensor cap carefully. 

 

Verify that the O-ring on the sensor head and water 
is in good condition. If needed, apply grease, or 
replace it with 1.5mm x 38mm O-ring.  

 

3. Replacing the battery: 

 

Remove the old battery from battery cover and 
disconnect it from the battery connector, . 

 

Place the battery cover on the new 9V battery and 
connect to battery connector.  

 

4. Assemble & Test: 

 

Once the battery has been replaced, check there 
are no objects in front of the sensor. 

 

Wait 15 seconds to allow the system to set the ideal 
sensor range. 

IMPORTANT

: Spent batteries should not be disposed of with normal household waste. Contact your local 

authority for information on waste disposal and recycling. 

 

 

 

 

 

Summary of Contents for Flowmatic TZ-FLOW225866

Page 1: ...Customizable settings by optional remote control sensor range security time delay In delay out and on off 24 hours mandatory hygiene flush option available upon request Chrome plated assembly for dura...

Page 2: ...reflective material such as stainless steel 3 If a sink strainer is straight below the faucet sensor use a strainer with a non reflective finish do not use a chrome plated one PREPARATION FOR INSTALLA...

Page 3: ...er supply Thread tape sealant should be used Ensure the thread tape doesn t obscure the inlet tail opening Connect inlet tail to water inlet Tighten inlet tail ensuring it cannot be turned once instal...

Page 4: ...ol hold the remote control straight in front of the sensor at a distance of about 6 8 15 20cm Choose the function you want to adjust by pressing once on one of the function buttons After pressing once...

Page 5: ...n is ideal to perform any kind of activity in front of the sensor without operating the system for example cleaning The product will remain shut for 1 minute when this button is pressed once To cancel...

Page 6: ...sensor cap carefully Verify that the O ring on the sensor head and water is in good condition If needed apply grease or replace it with 1 5mm x 38mm O ring 3 Replacing the battery Remove the old batte...

Page 7: ...to the inlet tail Ensure the sensor is aligned facing down Secure the body with M5 grub screw using the supplied Allen key AERATOR CLEANING INSTRUCTIONS 1 Disassemble and Clean Using an adjustable spa...

Page 8: ...nsor flashes once when user s hands are within the sensor s range The water supply pressure is higher than 500 kPa Reduce the supply water pressure Water flow from spout does not stop 1 Led in the sen...

Page 9: ...rer s warranty During the warranty period Galvin Engineering will replace or repair any defective products manufactured by Galvin Engineering without charge so long as the terms of the Manufacturer s...

Reviews: