background image

 

Version 2, 16

th

 March 2021, Page 

2

 of 

9

 

 

PRE-INSTALLATION  

 

WARNING 

1) To avoid reflection problems, keep a distance of more than 300 mm 
between the sink and the spout. 
2) This faucet model, with an infrared sensor pointing down, is not 
intended to be used together with a sink of a reflective material such as 
stainless steel. 
3) If a sink strainer is straight below the faucet sensor, use a strainer with 
a non-reflective finish (do not use a chrome plated one). 

 

PREPARATION FOR INSTALLATION 

 

Flush the water supply lines thoroughly before installing the faucet. Do not allow dirt, thread tape or metal 
particles to enter the faucet. Shut off water supply. 

 

Drill 28 -29 mm of hole at desired place to install the faucet.  

TOOLS REQUIRED

 

  Thread tape

 

  Adjustable spanner

 

Summary of Contents for Flowmatic TZ-FLOW225866

Page 1: ...Customizable settings by optional remote control sensor range security time delay In delay out and on off 24 hours mandatory hygiene flush option available upon request Chrome plated assembly for dura...

Page 2: ...reflective material such as stainless steel 3 If a sink strainer is straight below the faucet sensor use a strainer with a non reflective finish do not use a chrome plated one PREPARATION FOR INSTALLA...

Page 3: ...er supply Thread tape sealant should be used Ensure the thread tape doesn t obscure the inlet tail opening Connect inlet tail to water inlet Tighten inlet tail ensuring it cannot be turned once instal...

Page 4: ...ol hold the remote control straight in front of the sensor at a distance of about 6 8 15 20cm Choose the function you want to adjust by pressing once on one of the function buttons After pressing once...

Page 5: ...n is ideal to perform any kind of activity in front of the sensor without operating the system for example cleaning The product will remain shut for 1 minute when this button is pressed once To cancel...

Page 6: ...sensor cap carefully Verify that the O ring on the sensor head and water is in good condition If needed apply grease or replace it with 1 5mm x 38mm O ring 3 Replacing the battery Remove the old batte...

Page 7: ...to the inlet tail Ensure the sensor is aligned facing down Secure the body with M5 grub screw using the supplied Allen key AERATOR CLEANING INSTRUCTIONS 1 Disassemble and Clean Using an adjustable spa...

Page 8: ...nsor flashes once when user s hands are within the sensor s range The water supply pressure is higher than 500 kPa Reduce the supply water pressure Water flow from spout does not stop 1 Led in the sen...

Page 9: ...rer s warranty During the warranty period Galvin Engineering will replace or repair any defective products manufactured by Galvin Engineering without charge so long as the terms of the Manufacturer s...

Reviews: