© Galvin Engineering Pty Ltd
Product Installation Guidelines
Version 1, 19 October 2022, Page
8
of
24
7. Fit the faceplate
-
Fit the faceplate in position, it will be held
in place by a set of magnets.
-
Ensure the backnut is supporting the
faceplate.
-
Insert the flange and screw in the locking
nut.
-
Lock the locking nut using grub screw.
8. Install Spout and plug
-
Ensure there are two O-rings on the inner
part of the spout before installing the outer
spout.
-
Push spout to the end and lock with grub
screw to secure.
-
Ensure the disinfecton key cover is fitted
to the open hole as shown
7.1
OPERATION AND TESTING
After installation, check for leaks and correct operation.
Hand Movement (Wave on/Wave off) activates the mechanism and delivers the water with
the pre-set temperature.
7.2
SENSOR SETTING INSTRUCTIONS
Signs and
symbols
Touch function
Hand/object within sensor area
Water flows
LED flashes Green
Water flow stops
LED flashes Red
H
–
hours / min.
–
minutes / sec. - seconds
XXX
Locking nut
Grub Screw
Flange
Backnut
O-rings