© Galvin Engineering Pty Ltd
Product Installation Guidelines
Version 1, 19 October 2022, Page
6
of
24
IMPORTANT: Galvin Specialised products must be installed in accordance with these installation
instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water
and/or electrical supply conditions must also comply to the applicable national and/or state standards.
Failing to comply with these provisions shall void the product warranty and may affect the performance of
the product.
1. Fit box and connect with mains
−
Create an opening on the left or right side
of the box. Push the transformer cable
through the supplied grommet and leave
around 150mm of free cable inside the
box.
−
Using suitable fittings, attach the box
inside the wall. Box must be leveled and
installed parallel to the finished wall.
Ensure the box is not twisted.
−
Connect supplied inlets to the
thermostatic mixer and then with mains.
Attach the middle section of the box.
−
Attach one part of the supplied 3M Dual
Lock fastener on the relay unit, and the
other one in the most convenient spot of
the box. Recommended position shown
on the picture above. Align both sides of
the fastener and press the relay unit to fix
it on the box.
−
Check if the isolating valves are in the
‘C O E’ p s t n
Note:
Avoid using heat for soldering near the mixer
box and inlets.
2. Preparation for wall finishing
−
Fix installation cover to protect the mixer
against dust.
−
Leave cover attached until wall is
finished.
Temperature Sensor
Relay Unit
Middle section of box
Installation cover
Transformer cable
Sensor connection cable