3. Insert spout (without faceplate and flange) and
secure.
4. Using wrench size 23mm untight the tightening
ring
t v te the ‘C nt nu us run’ fun t n and
using wrench 16mm adjust the temperature by
turning the adjustment rod in direction marked
on the body. When the mixing temperature is
set, holding the adjustment rod tight the
tightening ring to prevent changing the
adjustment.
t p the ‘C nt nues run’ fun t n
Note:
Turning the adjustment rod clockwise will decreasing the
mixed water temperature and turning it counterclockwise will
increasing the mixed water temperature (see marking on the body).
5.
t v te the “Temp r ry Off” fun t n nd re ssem e the f ep te nd sp ut
Spout
Faceplate
Flange
Locking nut
Spout
Spout
Tightening ring