15
01.02.2021
Cod. 80005820a - GB
5.1 Positioning the refrigerated cabinet
_____________________________
For
unloading and handling
the cabinet with a forklift, we recommend using the marked handling points as given in
this manual.
We remind you that the use of forklift is
exclusively allowed
to authorized and properly trained personnel. Dur-
ing the unloading, positioning and installing phases, the personnel should wear suitable personal protection equipment
(i.e. protective gloves, glasses and reinforced shoes).
Place the unit, still packed, in the final installation position
in the store.
Please see the sections below.
The cabinet cannot be used outdoors
. Check the environmental conditions in which the unit will be installed
and match the climate class given on the unit’s identification plate (i.e climate class 3, max room temperature of 25°
C, R.H. 60 %). Higher levels of temperature and/or relative humidity can cause higher energy consumptions and poor-
er performances, consequently shortening the shelf
-
life of the displayed products.
Avoid the exposure of the cabinet to direct sunlight
, don’t place the unit close to heat sources such as ov-
ens, heating radiators, high
-
intensity lighting systems and any other heating source.
The unit should not be subject to air flows with a speed higher than 0.2 m/sec. It is highly recommended
that the unit is positioned far from doors, windows and air conditioning grids.
Make sure there is a
frequent change of air
in the room where the unit is operating even when the store is
closed.
The refrigerated cabinet base is designed to guarantee a proper ventilation of the condensing unit; therefore do
not obstruct the
air intakes
by placing any type of materials along its external perimeter
To avoid the condensation formation keep a space of 5 cm from the thermopane back
-
side panel.
5. Setting up the unit
Summary of Contents for Viessmann Tecto CI1 Series