![Galil Motion Control RIO-47 series
RIO-47100 User Manual Download Page 54](http://html1.mh-extra.com/html/galil-motion-control/rio-47-series-rio-47100/rio-47-series-rio-47100_user-manual_558776054.webp)
AQ
Input Range
AQ 0,1
Set input 0 to have
±
5V input range
AQ 1,2
Set input 1 to have
±
10V input range
AQ 2,3
Set input 2 to have 0-5V input range
AQ 3,4
Set input 3 to have 0-10V input range
Table 4.7: Setting Input Ranges on the RIOs with the ±10V configurable option
Setting Differential Mode
The AQ command also allows the RIO to change the configuration from the default 8 single ended analog
inputs to 4 differential analog inputs.
AQ
Differential Pairs
AQ 0,-1
Input 0 & Input 1 and
±
5V input range
AQ 2,-2
Input 2 & Input 3 and
±
10V input range
AQ 4,-3
Input 4 & Input 5 and 0-5V input range
AQ 6,-4
Input 6 & Input 7 and 0-10V input range
Table 4.8: Differential analog input channels on RIO's with the ±10V configurable option
Chapter 4 I/O ▫ 54 RIO-47xxx Rev. 1.0r