![Galil Motion Control RIO-47 series
RIO-47100 User Manual Download Page 114](http://html1.mh-extra.com/html/galil-motion-control/rio-47-series-rio-47100/rio-47-series-rio-47100_user-manual_558776114.webp)
Specifications
Number of Inputs
6 Thermocouple Inputs
Thermocouple input – Analog Input Map
TC[0:5] = AI[0:5]
Range
1
Type K (default) 0 – 345 deg C
Type E
0 – 230 deg C
Type J
0 – 270 deg C
Type T
0 – 345 deg C
Voltage Constant
2
Type K (default) 10.15 mV/deg C
Type E
15.225 mV/deg C
Type J
12.925 mV/deg C
Type T
10.15 mV/deg C
1
Contact Galil if required temperatures are outside of listed ranges.
2
Voltage Constant will change if Range is modified
Wiring
The SCB-483x6 has qty 6 thermocouple inputs. The thermocouples interfacing to the SCB-483x6 must
have an Ungrounded or Exposed Junction; contact Galil if Grounded Junction (Figure A2.4)
thermocouples are required. The wiring of the thermocouple to the SCB-483x6 is shown in Figure
A2.3 below.
A2 – SCB-48306/48316 ▫ 114 RIO-47xxx Rev. 1.0r
Figure A2.3: Thermocouple Wiring to SCB-483x6
Figure A2.4: Grounded Thermocouple Input - Not supported with SCB-483x6