![Galil Motion Control RIO-47 series
RIO-47100 User Manual Download Page 113](http://html1.mh-extra.com/html/galil-motion-control/rio-47-series-rio-47100/rio-47-series-rio-47100_user-manual_558776113.webp)
A2 – SCB-48306/48316
Description
The SCB-48306 and the SCB-48316 Signal Conditioning Board interface to up to 6 thermocouples. The
SCB-483x6 boards are designed to work with the RIO-4712x or RIO-47142. The SCB-48316 provides
thermocouple terminal connectors for the 6 thermocouple inputs, the SCB-48306 provides screw
terminals inputs for the 6 thermocouple inputs. Both SCB boards provide screw terminal connections
for Analog inputs 6 and 7 (AI6:7), all 8 analog outputs (AO0:7) and two GND terminals.
The SCB-48306 can plug directly into the Analog 26-pin high-density D-sub connector and will use
Analog inputs 0-5 on the RIO for the 6 thermocouple inputs. (TC[0:5] = AI[0:5]).
1
It is oriented
vertically from the RIO connector as shown in Figure A2.1. Other mounting options are available
upon request.
By default the SCB-483x6 will be setup for type K thermocouple inputs. Types E, J and T are also
available. The thermocouples interfacing to the SCB-483x6 must have an Ungrounded or Exposed
Junction (aka Floating Junction); contact Galil if Grounded Junction thermocouples are required.
1
Analog inputs 0-5 will not be available for general use analog inputs when the SCB-483x6 is connected to the RIO.
A2 – SCB-48306/48316 ▫ 113 RIO-47xxx Rev 1.0r
Figure A2.2: SCB-48316
Figure A2.1: SCB-48306 on RIO-47120